Skip to content
TapBuff

Denton Estates Mobile Home Park

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals, plus violations since 2016, with the certification that handles each result.

Serves
156 people
Connections
52
Water source
Groundwater
Based in
Collinsville, TX
County
Denton
Owner
Private
The ZIP code it serves

76207

The short answer

Nothing in EPA’s and Texas’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, not everything. 2 health-based violations since 2016.

What was found

Nitrate, haloacetic acids (HAA5) and total trihalomethanes (TTHM): Texas’s own results, samples taken from June 24, 2020 to July 9, 2021, with EPA’s 2012 to 2019 file for earlier years.

Fluoride, chromium (total) and arsenic: EPA’s compliance monitoring file, samples taken from Sept. 26, 2012 to Sept. 28, 2016. Newer results are in the utility’s annual water quality report.

Below EPA’s limits3

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.49ppm

Highest yearly average, 2013 to 2016

2016, one sample: 0.46 ppm

Averaged by year, the highest was 0.49 ppm, in 2013, below EPA’s legal limit of 4.0 ppm. In 2016, the latest year on file, its one sample was 0.46 ppm.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

3.6ppb

Highest yearly average, 2012 to 2016

Averaged by year, the highest was 3.6 ppb, in 2016, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.032ppm

Highest sample; found in 2 of 2

2021, one sample: 0.032 ppm

The highest sample, in 2021, was 0.032 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was 0.032 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.027 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Haloacetic acids (HAA5)
  • Total trihalomethanes (TTHM)

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Revised Total Coliform RuleFixes required after coliform results were not made on time.EPA: Treatment Technique, Corrective/Expedited Actions (RTCR)Dec. 6, 2025—Unaddressed
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Unaddressed
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 411 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride, chromium (total) and arsenic come from EPA’s file alone, which ends in 2019. Denton Estates Mobile Home Park’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from June 24, 2020 to July 9, 2021; EPA’s compliance samples are from Sept. 26, 2012 to Sept. 28, 2016.

Testing your own tap

Denton Estates Mobile Home Park’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Denton Estates Mobile Home Park serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, LLC -Dallas TX

    Allen, TX · about 29 miles

    Certified for bacteria

    (972) 727-1123

  • Pace Analytical Services, LLC -Dallas TX

    Fort Worth, TX · about 29 miles

    Certified for bacteria

    (817) 616-5030

  • Eurofins Xenco, LLC -Dallas

    Dallas, TX · about 30 miles

    Certified for bacteria

    (281) 240-4200

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources