Countryside Acres HOA
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 45 people
- Connections
- 15
- Water source
- Groundwater
- Based in
- Stanton, TX
- County
- Midland
- Owner
- Local government
The short answer
3 results are above EPA’s legal limit, and 1 more is above the health goal. The worst: Arsenic, above the legal limit. 16 health-based violations since 2016.
What handles itWhat was found
Arsenic, nitrate, fluoride, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM) and chromium (total): Texas’s own results, samples taken from Sept. 12, 2024 to Sept. 9, 2026.
Above the legal limit3
Arsenic
Comes from the source
19.4ppb
Highest yearly average, 2024 to 2026
2026 average: 17.8 ppb
Averaged by year, the highest was 19.4 ppb, in 2025, about twice EPA’s legal limit of 10 ppb. Its highest single sample was 22.9 ppb. In 2026, the latest year on file, its three samples averaged 17.8 ppb, above the limit. EPA recorded violations for arsenic at this utility in 2025 and 2026.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Nitrate
Comes from the source
13.1ppm
Highest sample; found in 9 of 9
2026 average: 11.8 ppm
From 2024 to 2026, nine samples were above EPA’s legal limit of 10 ppm, the highest 13.1 ppm in 2025. The next sample at the same point, within 30 days, kept the average above the limit for one; eight have no follow-up sample on file within 30 days. In 2026, the latest year on file, its three samples averaged 11.8 ppm, above the limit. EPA recorded violations for nitrate at this utility in 2024, 2025 and 2026.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
4.6ppm
Highest yearly average, 2024 to 2026
2026 average: 4.3 ppm
Averaged by year, the highest was 4.6 ppm, in 2024, above EPA’s legal limit of 4.0 ppm. Its highest single sample was 4.7 ppm. In 2026, the latest year on file, its three samples averaged 4.3 ppm, above the limit. EPA recorded violations for fluoride at this utility in 2025 and 2026.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Above the health goal1
Uranium
Comes from the source
8.3ppb
Highest yearly average, 2024
Averaged by year, the highest was 8.3 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Uranium”
Below EPA’s limits2
Haloacetic acids (HAA5)
Forms or is added in treatment
33.1ppb
Highest yearly average, 2024 to 2026
2026, one sample: 19.6 ppb
Averaged by year, the highest was 33.1 ppb, in 2024, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, its one sample was 19.6 ppb.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM)
Forms or is added in treatment
8.9ppb
Highest yearly average, 2024 to 2026
2026, one sample: 8.8 ppb
Averaged by year, the highest was 8.9 ppb, in 2024, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was 8.8 ppb.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Lead
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Nitrate/Nitrite (30 ppm challenge), Fluoride
For: Arsenic, Nitrate, Fluoride
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Nitrate/Nitrite Reduction, Fluoride Reduction, Uranium
For: Arsenic, Nitrate, Fluoride, Uranium
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level); Nitrate
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic, Nitrate, Fluoride
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Nitrate, Fluoride
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Fluoride
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 58checked Oct. 9, 2026
Certified for: Arsenic, Fluoride
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Nitrate, Fluoride
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2026 to June 30, 2026 | 4.5 MG/L | Archived |
| Arsenic | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2026 to June 30, 2026 | 0.019 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | April 1, 2026 to June 30, 2026 | 12 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Jan. 1, 2026 to March 31, 2026 | 12 MG/L | Archived |
| Arsenic | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2026 to March 31, 2026 | 0.019 MG/L | Archived |
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2026 to March 31, 2026 | 4.5 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2025 to Dec. 31, 2025 | 12 MG/L | Archived |
| Arsenic | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2025 to Dec. 31, 2025 | 0.019 MG/L | Archived |
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2025 to Dec. 31, 2025 | 4.5 MG/L | Archived |
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025 | 4.5 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | July 1, 2025 to Sept. 30, 2025 | 13 MG/L | Archived |
| Arsenic | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025 | 0.018 MG/L | Archived |
| Arsenic | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2025 to June 30, 2025 | 0.013 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | April 1, 2025 to June 30, 2025 | 12 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Jan. 1, 2025 to March 31, 2025 | 11 MG/L | Archived |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2024 to Dec. 31, 2024 | 12 MG/L | Archived |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 19 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Arsenic, nitrate, fluoride, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM) and chromium (total) results here are Texas’s own from 2024 on, with EPA’s national file for 2012 to 2019. Countryside Acres HOA’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Sept. 12, 2024 to Sept. 9, 2026.
Testing your own tap
No lab Texas certifies is within 75 miles of the area Countryside Acres HOA serves on the state’s list. Some take samples by mail; the state’s page lists them all.
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1650174. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 4 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Arsenic
- Get the utility’s own reportCountryside Acres HOA must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs