Skip to content
TapBuff

Coryell City Water Supply District

EPA’s and Texas’s records have results for 38 contaminants in its water; 6 were found.

Serves 6,042 people · Surface water bought from another system · Gatesville, TX

Serves
6,042 people
Connections
2,014
Water source
Surface water bought from another system
Based in
Gatesville, TX
County
Coryell
Owner
Local government
The 7 ZIP codes it serves

76528, 76538, 76561, 76597, 76638, 76657, 76689

The short answer

None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. 5 health-based violations since 2016, all resolved in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

The 5 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 13 to Oct. 7, 2025.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium: Texas’s own results, samples taken from Jan. 15, 2020 to July 7, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 6.1 ppt: see it below.

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

61.9 ppb

Highest sample, Oct. 7, 2025; found in 4 of 12

The highest sample was 61.9 ppb, about 6.2 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 4 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 46.2 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 29.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 46.2 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 92.2 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 91.4 ppb, in 2015, and EPA recorded violations in 2015 and 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 22.9 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 10.8 ppb · Forms or is added in treatment

Averaged by year, the highest was 22.9 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 49.3 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 56 ppb, in 2015, and EPA recorded a violation in 2016.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.3 ppm

Highest yearly average, 2020 to 2026 · 2026 average: 0.29 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.3 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.59 ppm. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.21 ppm, in 2014.

What handles it

About fluoride
Nitrate, Legal limit 10 ppm; highest 0.46 ppm

Highest sample; found in 20 of 24 · 2026 average: 0.18 ppm · Comes from the source

The highest sample, in 2024, was 0.46 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its four samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 1.1 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Texas utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFBA6.1 ppt7 of 12None covers it
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Lead
  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

5 health-based violations since 2016, 2 for total Haloacetic Acids (HAA5), 2 for TTHM and 1 for the Revised Total Coliform Rule. The latest began Dec. 21, 2018.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Revised Total Coliform RuleColiform results required a check of the system, and the check or its fixes were not done on time.EPA: Treatment Technique, Level 1 Assessment (RTCR)Dec. 21, 2018Resolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 2016, 63 ppbResolved
April 1, 2016 to June 30, 2016, 61 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 2016, 97 ppbResolved
Jan. 1, 2016 to March 31, 2016, 91 ppbResolved

Health-based violations only. 19 monitoring or reporting violations not shown.

Disinfectant

Coryell City Water Supply District reported adding chloramine before water enters its pipes, at all 3 of its sampling points, in its 2025 sampling for EPA.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Coryell City Water Supply District’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 13 to Oct. 7, 2025; Texas’s results run from Jan. 15, 2020 to July 7, 2026.

Testing your own tap

Coryell City Water Supply District’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Coryell City Water Supply District’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Coryell City Water Supply District’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Texas certifies closest to the area Coryell City Water Supply District serves, or a kit by mail

The 3 labs Texas certifies closest to the area Coryell City Water Supply District serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Bio-Chem Lab, Inc.

    West, TX · about 35 miles

    Certified for bacteria, lead and copper

    (254) 829-8001

  • Environmental Monitoring Lab

    Hillsboro, TX · about 45 miles

    Certified for bacteria

    (254) 582-2622

  • Texas Institute for Applied Environmental Research (TIAER)

    Stephenville, TX · about 63 miles

    Certified for bacteria

    (254) 968-9570

All 80 certified labs for Texas⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID TX0500013. Rebuilt from EPA data on Oct. 25, 2026.