Skip to content
TapBuff

Coleto Water

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
540 people
Connections
180
Water source
Groundwater
Based in
Saint Louis, TX
County
Victoria
Owner
Private
The ZIP code it serves

77905

The short answer

3 results are above the health goal. The worst: Arsenic, above the health goal. 4 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1994 to 2025.

Arsenic, uranium, fluoride, haloacetic acids (HAA5), chromium (total), nitrate and total trihalomethanes (TTHM): Texas’s own results, samples taken from July 29, 2020 to Sept. 24, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal3

Arsenic

Comes from the source

Above the health goal

6.1ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 6.1 ppb, in 2024: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.4 ppb, in 2015.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Lead

Comes from pipes, often your own

Above the health goal

3.0ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Uranium

Comes from the source

Above the health goal

5.3ppb

Highest yearly average, 2021

Averaged by year, the highest was 5.3 ppb, in 2021: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.3 ppb, in 2015.

What handles it

Below EPA’s limits2

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.51ppm

Highest yearly average, 2021 to 2024

2024, one sample: 0.51 ppm

Averaged by year, the highest was 0.51 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 0.51 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.59 ppm, in 2012.

What handles it

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.5ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 1.5 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2025, the latest year on file, it wasn’t found in its one sample.

What handles it

No certification claim covers this compound yet.

3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Nitrate
  • Total trihalomethanes (TTHM)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction, Uranium

    For: Arsenic, Lead, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Revised Total Coliform RuleFixes required after coliform results were not made on time.EPA: Treatment Technique, Corrective/Expedited Actions (RTCR)July 26, 2020—Resolved
Revised Total Coliform RuleColiform or E. coli results required a detailed review of the system, and it or its fixes were not done on time.EPA: Treatment Technique, Level 2 Assessment (RTCR)May 21, 2017—Resolved
Revised Total Coliform RuleColiform or E. coli results required a detailed review of the system, and it or its fixes were not done on time.EPA: Treatment Technique, Level 2 Assessment (RTCR)April 29, 2017—Resolved
Revised Total Coliform RuleColiform results required a check of the system, and the check or its fixes were not done on time.EPA: Treatment Technique, Level 1 Assessment (RTCR)March 26, 2017—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 67 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, uranium, fluoride, haloacetic acids (HAA5), chromium (total), nitrate and total trihalomethanes (TTHM) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Coleto Water’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from July 29, 2020 to Sept. 24, 2026.

Testing your own tap

Coleto Water’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Coleto Water serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, LLC -Dallas TX

    Victoria, TX · about 6 miles

    Certified for bacteria

    (361) 465-7989

  • Victoria County Public Health Department Water Laboratory

    Victoria, TX · about 6 miles

    Certified for bacteria

    (361) 578-6281

  • Corpus Christi -Nueces County Public Health District Laboratory

    Corpus Christi, TX · about 72 miles

    Certified for bacteria

    (361) 826-7213

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX2350036. Rebuilt from EPA data on Oct. 18, 2026.