City of White Oak
EPA’s and Texas’s records have results for 38 contaminants in its water; 4 were found.
Serves 6,469 people · Surface water · White Oak, TX
- Serves
- 6,469 people
- Connections
- 2,643
- Water source
- Surface water
- Based in
- White Oak, TX
- County
- Gregg
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 22 to Nov. 14, 2023.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic, chromium (total) and uranium: Texas’s own results, samples taken from March 3, 2020 to Sept. 3, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 4 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 38.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 11.9 ppb · Forms or is added in treatment
Averaged by year, the highest was 38.1 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 66 ppb. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 99.1 ppb, in 2012.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 27.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 15.3 ppb · Forms or is added in treatment
Averaged by year, the highest was 27.1 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 39.5 ppb. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 78 ppb, in 2012.
What handles it
No certification claim covers this compound yet.
Nitrate, Legal limit 10 ppm; highest 0.27 ppm
Highest sample; found in 7 of 7 · 2026, one sample: 0.13 ppm · Comes from the source
The highest sample, in 2021, was 0.27 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.3 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.042 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.036 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.042 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.17 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
34 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
- Lead
- Uranium
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 4 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
City of White Oak reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA. It also reported chlorine dioxide and permanganate.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of White Oak’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 22 to Nov. 14, 2023; Texas’s results run from March 3, 2020 to Sept. 3, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of White Oak’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Texas certifies closest to the area City of White Oak serves, or a kit by mail
The 3 labs Texas certifies closest to the area City of White Oak serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Southern Petroleum Laboratories (SPL), Inc. (FKA Ana-Lab Corporation)
Kilgore, TX · about 10 miles
Certified for bacteria, lead and copper
Environmental Monitoring Lab
Winona, TX · about 15 miles
Certified for bacteria
Northeast Texas Public Health District Laboratory
Tyler, TX · about 29 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportCity of White Oak must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX0920006. Rebuilt from EPA data on Oct. 25, 2026.