- Serves
- 173 people
- Connections
- 148
- Water source
- Groundwater
- Based in
- Midway, TX
- County
- Madison
- Owner
- Local government
The ZIP code it serves
The short answer
1 result is above EPA’s legal limit. The worst: Total trihalomethanes (TTHM), above the legal limit. 2 health-based violations since 2016.
What handles itWhat was found
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.4 ppm, for the period ending June 30, 1995. None since is on file, so it is not counted as a current finding.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium: Texas’s own results, samples taken from Oct. 28, 2020 to Sept. 16, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Total trihalomethanes (TTHM)
Forms or is added in treatment
105ppb
Highest yearly average, 2021 to 2026
2026 average: 73.4 ppb
Averaged by year, the highest was 105 ppb, in 2024, above EPA’s legal limit of 80 ppb. Its highest single sample was 112 ppb. In 2026, the latest year on file, its three samples averaged 73.4 ppb. EPA recorded a violation for total trihalomethanes (TTHM) at this utility in 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 12 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Below EPA’s limits3
Haloacetic acids (HAA5)
Forms or is added in treatment
51ppb
Highest yearly average, 2021 to 2026
2026 average: 40.1 ppb
Averaged by year, the highest was 51 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 59.3 ppb. In 2026, the latest year on file, its three samples averaged 40.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 19.1 ppb, in 2017.
What handles it
No certification claim covers this compound yet.
Fluoride
Forms or is added in treatment
0.52ppm
Highest yearly average, 2021 to 2024
2024, one sample: 0.46 ppm
Averaged by year, the highest was 0.52 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 0.46 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.18ppm
Highest sample; found in 7 of 7
2026, one sample: 0.18 ppm
The highest sample, in 2026, was 0.18 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was 0.18 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.086 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Trihalomethanes (TTHM) Reduction
For: Total trihalomethanes (TTHM)
Other certifiers’ wording: VOC Reduction
- NSF/ANSI 58
Claim: Trihalomethanes (TTHM) Reduction
For: Total trihalomethanes (TTHM)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Brita Hub Countertop Water Filter System (87340)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Ninja HydraSense Countertop Water Filtration System (WF1001)
Countertop
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
PUR PLUS Faucet Filtration System, Horizontal (PFM400H)
Faucet mount
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
Certified for: Total trihalomethanes (TTHM)
Brita Elite Water Filter Faucet System (SAFF-100/FF-100)
Faucet mount
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
Certified for: Total trihalomethanes (TTHM)
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025 | 0.085 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2025 to June 30, 2025 | 0.09 MG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. | ||||
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Midway’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Oct. 28, 2020 to Sept. 16, 2026.
Testing your own tap
The 3 labs Texas certifies closest to the area City of Midway serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Chaparral Laboratories, Inc.
Huntsville, TX · about 14 miles
Certified for bacteria, lead and copper
Eastex Environmental Lab, Inc. -Coldspring
Coldspring, TX · about 40 miles
Certified for bacteria, lead and copper
Nova Biologicals, Inc.
Conroe, TX · about 48 miles
Certified for bacteria
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1570003. Rebuilt from EPA data on Oct. 18, 2026.
Towns it serves
Also in Madison County
- City of Madisonville6,111
- Tdcj Ferguson Unit3,043
- North Zulch MUD1,800
- High Prairie Water Supply Corp1,476
What to do next
- Read up on Total trihalomethanes (TTHM)What each one does to health, where it comes from, and the certification claim that addresses it.About Total trihalomethanes (TTHM)
- Get the utility’s own reportCity of Midway must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs