City of Marlin water quality report, rewritten
- Serves
- 5,967
- Connections
- 3,010
- Water source
- Surface water
- Based in
- Marlin, TX
- County
- Falls
- Owner
- Local government
The ZIP code it serves
PWSID TX0730002 · EPA data
Read this first
Nothing in the federal data for this utility is above a health goal. That covers PFAS, lithium, lead and copper; it does not cover everything, so read what this report cannot tell you below.
33 health-based violations since 2016. Details are below.
What was found
Highlighted: above the health goal, or EPA’s health benchmark where there is no goal. Circled: above the legal limit in at least one sample, or the action level. Every scale puts that line at its middle.
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 6.2 ppt | 1 of 2 | None covers it |
Tested and not found
Below EPA’s minimum reporting level in every sample taken from March 12, 2025 to Dec. 18, 2025. Not found means not measured above that level, which is not the same as zero.
All 30 compounds tested and not found
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lead
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2026 to June 30, 2026 | 0.062 MG/L | Unaddressed |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2026 to March 31, 2026 | 0.15 MG/L | Archived |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2026 to March 31, 2026 | 0.1 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2025 to Dec. 31, 2025 | 0.1 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2025 to Dec. 31, 2025 | 0.14 MG/L | Archived |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025 | 0.13 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025 | 0.11 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2025 to June 30, 2025 | 0.11 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2025 to June 30, 2025 | 0.14 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2024 to Sept. 30, 2024 | 0.082 MG/L | Archived |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2024 to June 30, 2024 | 0.087 MG/L | Archived |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2024 to June 30, 2024 | 0.084 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2024 to March 31, 2024 | 0.065 MG/L | Archived |
| Long Term 2 Enhanced Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | April 1, 2021 to April 30, 2021 | — | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021 | 0.067 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020 | 0.07 MG/L | Resolved |
| Long Term 2 Enhanced Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | July 1, 2020 to July 31, 2020 | — | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020 | 0.065 MG/L | Resolved |
| Revised Total Coliform Rule | Fixes required after coliform results were not made on time.EPA: Treatment Technique, Corrective/Expedited Actions (RTCR) | June 1, 2020 | — | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2020 to June 30, 2020 | 0.078 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2020 to March 31, 2020 | 0.074 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2019 to Dec. 31, 2019 | 0.065 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2019 to Sept. 30, 2019 | 0.065 MG/L | Resolved |
| Revised Total Coliform Rule | Coliform results required a check of the system, and the check or its fixes were not done on time.EPA: Treatment Technique, Level 1 Assessment (RTCR) | Oct. 1, 2018 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | July 1, 2017 to July 31, 2017 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | June 1, 2017 to June 30, 2017 | — | Resolved |
| Long Term 2 Enhanced Surface Water Treatment Rule | Water drawn from a river, lake or reservoir was not filtered as required.EPA: Failure to Filter (SWTR) | Oct. 1, 2016 | — | Resolved |
| Long Term 2 Enhanced Surface Water Treatment Rule | Water drawn from a river, lake or reservoir was not filtered as required.EPA: Failure to Filter (SWTR) | Sept. 1, 2016 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | July 1, 2016 to July 31, 2016 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | June 1, 2016 to June 30, 2016 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | June 1, 2016 to June 30, 2016 | — | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2016 to June 30, 2016 | 0.069 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2016 to March 31, 2016 | 0.071 MG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 24 monitoring or reporting violations not shown. | ||||
What this report cannot tell you
- Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in City of Marlin’s own annual report, which it must send you every year.
- Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
- Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from March 12, 2025 to Dec. 18, 2025.
Other Texas utilities
- City of Houston3 million
- San Antonio Water System2.6 million
- Dallas Water Utility1.4 million
- City of Austin Water & Wastewater1.1 million
- City of Fort Worth955,900
- El Paso Water Utilities747,168
- City of Arlington413,955
- City of Corpus Christi318,387
- City of Plano292,059
- Lubbock Public Water System275,041
- City of Irving264,546
- City of Laredo260,046
Sources
- EPA UCMR 5 occurrence data, file of Aug. 27, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q2
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
What to do next
Nothing here is above a health goal
In the federal data for this utility. That data does not cover everything, which is why the next step matters.
Every contaminant TapBuff tracksGet the utility’s own report
City of Marlin must send you a water quality report every year. It lists nitrate, arsenic and byproduct levels this page cannot.
How to read itTest your own tap for lead
Your service line, solder and fixtures decide the lead at your faucet, not the utility’s average.
Lead in your water: what to doDecide if you want a filter at all
A filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.
NSF/ANSI standards, decoded