City of Laredo
EPA’s and Texas’s records have results for 38 contaminants in its water; 9 were found.
Serves 260,046 people · Surface water · Laredo, TX
- Serves
- 260,046 people
- Connections
- 88,747
- Water source
- Surface water
- Based in
- Laredo, TX
- County
- Webb
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. 7 health-based violations since 2016, 1 with no fix on record in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
Filters for lead, uranium and arsenic, if you want them lowerThe 7 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from June 7, 2023 to July 29, 2024.
Lead and copper: EPA SDWIS monitoring periods ending 2005 to 2024.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, uranium, arsenic and chromium (total): Texas’s own results, samples taken from Feb. 3, 2020 to Sept. 1, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 10.6 ppt: see it below.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
34.3 ppb
Highest sample, March 25, 2024; found in 8 of 8
The highest sample was 34.3 ppb, about 3.4 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 7 results
Lead, uranium and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 72 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 72 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 139 ppb. That was also the latest year on file. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 75.5 ppb, in 2015, and EPA recorded violations in 2012, 2013, 2015, 2016 and 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 46.9 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 37.3 ppb · Forms or is added in treatment
Averaged by year, the highest was 46.9 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 164 ppb. In 2026, the latest year on file, its 36 samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 31.4 ppb, in 2015.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.65 ppm
Highest yearly average, 2020 to 2025 · 2025 average: 0.64 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.65 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.72 ppm. In 2025, the latest year on file, its five samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.71 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate, Legal limit 10 ppm; highest 1.1 ppm
Highest sample; found in 29 of 30 · 2025 average: 0.65 ppm · Comes from the source
The highest sample, in 2024, was 1.1 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its five samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 1.1 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.4 ppb
90th percentile, 2022 to 2024 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 2.6 ppb
Highest yearly average, 2021 to 2024 · 2024 average: 1.7 ppb · Comes from the source
Averaged by year, the highest was 2.6 ppb, in 2021, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 3.6 ppb. In 2024, the latest year on file, its four samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 3.1 ppb, in 2015.
What handles it
- NSF/ANSI 58 look for “Uranium”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.42 ppb
Highest yearly average, 2020 to 2025 · 2025: not found · Comes from the source
Averaged by year, the highest was 0.42 ppb, in 2024, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 2.1 ppb. In 2025, the latest year on file, it wasn’t found in any of its five samples.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.3 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 10.6 ppt | 5 of 8 | None covers it |
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
7 health-based violations since 2016, 4 for TTHM, 2 for the Revised Total Coliform Rule and 1 for the Lead and Copper Rule Revisions. The latest began May 1, 2026, and 1 has no fix on record in EPA’s file.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Revised Total Coliform Rule | E. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR) | May 1, 2026 to May 31, 2026 | No fix on recordEPA: archived |
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | Resolved |
| Revised Total Coliform Rule | E. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR) | Oct. 1, 2024 to Oct. 31, 2024 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2017 to March 31, 2017, 107 ppb | Resolved |
| Oct. 1, 2016 to Dec. 31, 2016, 98 ppb | Resolved |
The other 2, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2016 to Sept. 30, 2016, 106 ppb | Resolved |
| April 1, 2016 to June 30, 2016, 104 ppb | Resolved |
Health-based violations only. 14 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Uranium, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Uranium, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover all 3 first
Disinfectant
City of Laredo reported adding chloramine before water enters its pipes, at all 2 of its sampling points, in its 2023 to 2024 sampling for EPA.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, uranium, arsenic and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Laredo’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 7, 2023 to July 29, 2024; Texas’s results run from Feb. 3, 2020 to Sept. 1, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of Laredo’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 1.4 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What City of Laredo’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The lab Texas certifies closest to the area City of Laredo serves, or a kit by mail
The lab Texas certifies closest to the area City of Laredo serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
City of Laredo Health Department Lab
Laredo, TX · about 5 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportCity of Laredo must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX2400001. Rebuilt from EPA data on Oct. 25, 2026.