City of Idalou

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,250 people
Connections
996
Water source
Groundwater
Based in
Idalou, TX
County
Lubbock
Owner
Local government
The ZIP code it serves

79329

The short answer

3 results are above the health goal. The worst: Arsenic, above the health goal. 36 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1995 to 2026.

Arsenic, uranium, fluoride, nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM) and chromium (total): Texas’s own results, samples taken from March 11, 2020 to July 21, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal3

Arsenic

Comes from the source

Above the health goal

8.0ppb

Highest yearly average, 2021 to 2025

2025 average: 7.3 ppb

Averaged by year, the highest was 8.0 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 8.7 ppb. In 2025, the latest year on file, its three samples averaged 7.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 9.1 ppb, in 2012, and EPA recorded a violation in 2012.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

15.6ppb

Highest yearly average, 2020 to 2026

2026, one sample: 11.3 ppb

Averaged by year, the highest was 15.6 ppb, in 2021: below EPA’s legal limit of 30 ppb, but above its health goal of zero. In 2026, the latest year on file, its one sample was 11.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 12.3 ppb, in 2015.

What handles it

Lead

Comes from pipes, often your own

Above the health goal

1.4ppb

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 1.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits5

Fluoride

Forms or is added in treatment

Below EPA’s limits

2.5ppm

Highest yearly average, 2020 to 2026

2026 average: 2.3 ppm

Averaged by year, the highest was 2.5 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 2.7 ppm. In 2026, the latest year on file, its three samples averaged 2.3 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.5 ppm, in 2012.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

4.5ppm

Highest sample; found in 26 of 26

2026 average: 4.1 ppm

The highest sample, in 2026, was 4.5 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its three samples averaged 4.1 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 7.6 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

15.4ppb

Highest yearly average, 2020 to 2026

2026, one sample: 1.3 ppb

Averaged by year, the highest was 15.4 ppb, in 2023, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, its one sample was 1.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 16.2 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

6.2ppb

Highest yearly average, 2020 to 2026

2026, one sample: 3.5 ppb

Averaged by year, the highest was 6.2 ppb, in 2025, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was 3.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.6 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Chromium (total)

Comes from the source

Below EPA’s limits

7.1ppb

Highest yearly average, 2021 to 2025

2025 average: 2.0 ppb

Averaged by year, the highest was 7.1 ppb, in 2021, below EPA’s legal limit of 100 ppb. In 2025, the latest year on file, its three samples averaged 2.0 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.1 ppb, in 2015.

What handles it

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium, Lead Reduction

    For: Arsenic, Uranium, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2026 to June 30, 20260.012 MG/LArchived
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2026 to March 31, 20260.012 MG/LArchived
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2025 to Dec. 31, 20250.011 MG/LArchived
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2025 to Sept. 30, 20250.009 MG/LArchived
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 20250.008 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 20250.008 MG/LArchived
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 20250.009 MG/LResolved
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2024 to Dec. 31, 20240.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2024 to Sept. 30, 20240.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2024 to June 30, 20240.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2024 to March 31, 20240.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2023 to Dec. 31, 20230.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2023 to Sept. 30, 20230.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 20230.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 20230.01 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 20220.009 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 20220.008 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 20220.01 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2021 to Dec. 31, 20210.01 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2021 to Sept. 30, 20210.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 20210.013 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 20210.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 20200.009 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 20200.009 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2020 to June 30, 20200.009 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 31, 20200.01 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Dec. 31, 20190.014 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 20190.015 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 20190.013 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2019 to March 31, 20190.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 20180.008 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 20170.008 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 20160.009 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 20160.011 MG/LResolved
1,1-DichloroethyleneThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 20160.009 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 15 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, uranium, fluoride, nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM) and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Idalou’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from March 11, 2020 to July 21, 2026.

Testing your own tap

City of Idalou’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The lab Texas certifies closest to the area City of Idalou serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Xenco, LLC -Lubbock

    Lubbock, TX · about 23 miles

    Certified for bacteria

    (806) 794-1296

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX1520001. Rebuilt from EPA data on Oct. 18, 2026.