Skip to content
TapBuff

City of Buckholts

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
365 people
Connections
190
Water source
Surface water bought from another system
Based in
Buckholts, TX
County
Milam
Owner
Local government
The ZIP code it serves

76518

The short answer

Nothing in EPA’s and Texas’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Texas’s own results, samples taken from Feb. 6, 2020 to May 12, 2026, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

50.7ppb

Highest yearly average, 2020 to 2026

2026 average: 43.4 ppb

Averaged by year, the highest was 50.7 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 82.7 ppb. In 2026, the latest year on file, its four samples averaged 43.4 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 154 ppb, in 2012, and EPA recorded violations in 2012, 2013, 2014 and 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

17.8ppb

Highest yearly average, 2020 to 2026

2026 average: 14.3 ppb

Averaged by year, the highest was 17.8 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 32.5 ppb. In 2026, the latest year on file, its four samples averaged 14.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 68.7 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

0.28ppm

Highest sample; found in 7 of 7

2026, one sample: 0.26 ppm

The highest sample, in 2025, was 0.28 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.26 ppm.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

Violations since 2016

No health-based violations on file with EPA since 2016. There are 45 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Buckholts’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 6, 2020 to May 12, 2026.

Testing your own tap

City of Buckholts’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area City of Buckholts serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Aqua-Tech Laboratories, Inc.

    Bryan, TX · about 41 miles

    Certified for bacteria, lead and copper

    (979) 778-3707

  • Integrity Testing, Inc.

    Austin, TX · about 48 miles

    Certified for lead and copper

    (512) 891-7777

  • Texas Department of State Health Services Laboratory Services Section

    Austin, TX · about 51 miles

    Certified for bacteria, lead and copper

    (512) 458-7318

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX1660007. Rebuilt from EPA data on Oct. 18, 2026.