Skip to content
TapBuff

City of Brownwood

EPA’s and Texas’s records have results for 34 contaminants in its water; 5 were found.

Serves 18,862 people · Surface water bought from another system · Brownwood, TX

Serves
18,862 people
Connections
9,191
Water source
Surface water bought from another system
Based in
Brownwood, TX
County
Brown
Owner
Local government
The ZIP code it serves

76801

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

Filters for lead, if you want it lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Sept. 19, 2023 to June 11, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2007 to 2026.

Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Texas’s own results, samples taken from Feb. 19, 2020 to July 9, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 10.8 ppt: see it below.

Below EPA’s limits, 4 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 54.8 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 40.4 ppb · Forms or is added in treatment

Averaged by year, the highest was 54.8 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 65.5 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 67.1 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 25.9 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 14.6 ppb · Forms or is added in treatment

Averaged by year, the highest was 25.9 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 63.5 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 44 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.1 ppb

90th percentile, 2024 to 2026 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 2.1 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.2 ppm

Highest sample; found in 4 of 6 · 2026: not found · Comes from the source

The highest sample, in 2020, was 0.2 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Texas utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFBA10.8 ppt4 of 4None covers it
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

Disinfectant

City of Brownwood reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 to 2024 sampling for EPA.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Brownwood’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Sept. 19, 2023 to June 11, 2024; Texas’s results run from Feb. 19, 2020 to July 9, 2026.

Testing your own tap

City of Brownwood’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of Brownwood’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 2.1 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 2 labs Texas certifies closest to the area City of Brownwood serves, or a kit by mail

The 2 labs Texas certifies closest to the area City of Brownwood serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Texas Institute for Applied Environmental Research (TIAER)

    Stephenville, TX · about 61 miles

    Certified for bacteria

    (254) 968-9570

  • Abilene–Taylor County Public Health District

    Abilene, TX · about 68 miles

    Certified for bacteria

    (325) 692-5600

All 80 certified labs for Texas⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID TX0250002. Rebuilt from EPA data on Oct. 25, 2026.