What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
595 people
Connections
238
Water source
Surface water bought from another system
Based in
San Jose, TX
County
Coryell
Owner
Private
The ZIP code it serves

76522

The short answer

1 result is above EPA’s legal limit. The worst: Haloacetic acids (HAA5), above the legal limit. 3 health-based violations since 2016.

What was found

Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate: Texas’s own results, samples taken from Feb. 25, 2020 to Sept. 15, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Haloacetic acids (HAA5)

Forms or is added in treatment

Above the legal limit

31.8ppb

Highest yearly average, 2020 to 2026

2026 average: 13.9 ppb

Averaged by year, the highest was 31.8 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 73.9 ppb. In 2026, the latest year on file, its six samples averaged 13.9 ppb. EPA judges this limit at each sampling point, and recorded a violation for haloacetic acids (HAA5) at this utility in 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 34.8 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Below EPA’s limits2

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

59.6ppb

Highest yearly average, 2020 to 2026

2026 average: 32.9 ppb

Averaged by year, the highest was 59.6 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 164 ppb. In 2026, the latest year on file, its six samples averaged 32.9 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 52.1 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.41ppm

Highest sample; found in 6 of 7

2026: not found

The highest sample, in 2024, was 0.41 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2024 to March 31, 20240.07 MG/LResolved
Revised Total Coliform RuleColiform results required a check of the system, and the check or its fixes were not done on time.EPA: Treatment Technique, Level 1 Assessment (RTCR)Jan. 11, 2019—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 44 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Cedar Grove Mobile Home Park’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 25, 2020 to Sept. 15, 2026.

Testing your own tap

Cedar Grove Mobile Home Park’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Cedar Grove Mobile Home Park serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Environmental Monitoring Lab

    Llano, TX · about 56 miles

    Certified for bacteria

    (325) 247-3295

  • Integrity Testing, Inc.

    Austin, TX · about 58 miles

    Certified for lead and copper

    (512) 891-7777

  • Texas Department of State Health Services Laboratory Services Section

    Austin, TX · about 63 miles

    Certified for bacteria, lead and copper

    (512) 458-7318

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX0500043. Rebuilt from EPA data on Oct. 18, 2026.