Caddo Village
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 1,395 people
- Connections
- 465
- Water source
- Groundwater
- Based in
- Austin, TX
- County
- Montgomery
- Owner
- Private
The ZIP code it serves
The short answer
3 results are above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2024.
Arsenic, fluoride, chromium (total), haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM): Texas’s own results, samples taken from Sept. 2, 2020 to June 8, 2026, with EPA’s 2012 to 2019 file for earlier years.
Uranium: EPA’s compliance monitoring file, samples taken from Aug. 15, 2019 to Aug. 15, 2019. Newer results are in the utility’s annual water quality report.
Above the health goal3
Arsenic
Comes from the source
4.2ppb
Highest yearly average, 2021 to 2024
2024: not found
Averaged by year, the highest was 4.2 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2024, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.2 ppb, in 2015.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Uranium
Comes from the source
4.6ppb
Highest yearly average, 2019
Averaged by year, the highest was 4.6 ppb, in 2019: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Uranium”
Lead
Comes from pipes, often your own
0.63ppb
90th percentile, 2022 to 2024
In the latest period, 9 in 10 homes sampled were at or below 0.63 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Below EPA’s limits1
Fluoride
Forms or is added in treatment
0.35ppm
Highest yearly average, 2022
Averaged by year, the highest was 0.35 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.35 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Haloacetic acids (HAA5)
- Nitrate
- Total trihalomethanes (TTHM)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium, Lead Reduction
For: Arsenic, Uranium, Lead
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic, Lead
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Lead
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Lead
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 10 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Arsenic, fluoride, chromium (total), haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Caddo Village’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Sept. 2, 2020 to June 8, 2026; EPA’s compliance samples are from Aug. 15, 2019 to Aug. 15, 2019.
Testing your own tap
The 3 labs Texas certifies closest to the area Caddo Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Nova Biologicals, Inc.
Conroe, TX · about 12 miles
Certified for bacteria
Eastex Environmental Lab, Inc. -Coldspring
Coldspring, TX · about 16 miles
Certified for bacteria, lead and copper
Chaparral Laboratories, Inc.
Huntsville, TX · about 26 miles
Certified for bacteria, lead and copper
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1700473. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 3 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Arsenic
- Get the utility’s own reportCaddo Village must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs