Skip to content
TapBuff

B B S WSC

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,455 people
Connections
485
Water source
Groundwater
Based in
Montalba, TX
County
Anderson
Owner
Local government
The 2 ZIP codes it serves

75803, 75853

The short answer

Nothing in EPA’s and Texas’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, chromium (total), nitrate, arsenic and uranium: Texas’s own results, samples taken from July 7, 2020 to Sept. 17, 2026, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits5

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

48.4ppb

Highest yearly average, 2020 to 2026

2026 average: 47.4 ppb

Averaged by year, the highest was 48.4 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 61.3 ppb. In 2026, the latest year on file, its two samples averaged 47.4 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 53.1 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

11.7ppb

Highest yearly average, 2020 to 2026

2026 average: 8.5 ppb

Averaged by year, the highest was 11.7 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 16 ppb. In 2026, the latest year on file, its two samples averaged 8.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 21.9 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.14ppm

Highest yearly average, 2021 to 2025

2025, one sample: 0.13 ppm

Averaged by year, the highest was 0.14 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 0.13 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.24 ppm, in 2012.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

2.5ppb

Highest yearly average, 2021 to 2024

2024: not found

Averaged by year, the highest was 2.5 ppb, in 2021, below EPA’s legal limit of 100 ppb. Its highest single sample was 2.8 ppb. In 2024, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.7 ppb, in 2018.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.044ppm

Highest sample; found in 14 of 14

2026 average: 0.041 ppm

The highest sample, in 2026, was 0.044 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its two samples averaged 0.041 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.06 ppm, in 2012.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Lead
  • Uranium

Violations since 2016

No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, chromium (total), nitrate, arsenic and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. B B S WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from July 7, 2020 to Sept. 17, 2026.

Testing your own tap

B B S WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area B B S WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Analytical Environmental Labs

    Tyler, TX · about 33 miles

    Certified for bacteria

    (903) 509-8700

  • Northeast Texas Public Health District Laboratory

    Tyler, TX · about 40 miles

    Certified for bacteria

    (903) 535-0090

  • Environmental Monitoring Lab

    Winona, TX · about 54 miles

    Certified for bacteria

    (903) 877-9222

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources