Skip to content
TapBuff

Township of Springdale

What EPA’s and Pennsylvania’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,600 people
Connections
754
Water source
Surface water bought from another system
Based in
Harwick, PA
County
Allegheny
Owner
Local government
The ZIP code it serves

15049

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Copper, above the action level. 2 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2019 to 2022.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Pennsylvania’s own results, samples taken from Aug. 14, 2020 to Aug. 20, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Copper

Comes from pipes, often your own

Above the action level

1.5ppm

90th percentile, 2022

In the latest period, 9 in 10 homes sampled were at or below 1.5 ppm, above EPA’s action level of 1.3 ppm.

What handles it

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

3.0ppb

90th percentile, 1996

In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits2

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

57.9ppb

Highest yearly average, 2020 to 2026

2026 average: 36 ppb

Averaged by year, the highest was 57.9 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 124 ppb. In 2026, the latest year on file, its two samples averaged 36 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 49.5 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

15.9ppb

Highest yearly average, 2020 to 2026

2026 average: 3.8 ppb

Averaged by year, the highest was 15.9 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 21.2 ppb. In 2026, the latest year on file, its two samples averaged 3.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.2 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Copper Reduction, Lead Reduction

    For: Copper, Lead

  • NSF/ANSI 58

    Claims: Copper Reduction, Lead Reduction

    For: Copper, Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyMarch 23, 2026—Unaddressed
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationApril 1, 2025—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 9 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Township of Springdale’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from Aug. 14, 2020 to Aug. 20, 2026.

Testing your own tap

Township of Springdale’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

The 3 labs Pennsylvania certifies closest to the area Township of Springdale serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Pittsburgh

    Pittsburgh, PA · about 4 miles

    Certified for bacteria

    (412) 963-7058

  • Dream Pools and Spas Inc

    Pittsburgh, PA · about 8 miles

    Certified for bacteria

    (412) 661-7665

  • RJ Lee Group, Inc.

    Monroeville, PA · about 9 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, PFAS, asbestos

    (724) 325-1776

Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.

All 108 certified labs for Pennsylvania

Sources

PWSID PA5020021. Rebuilt from EPA data on Oct. 18, 2026.