Sunrise Lakes Sec 12
What EPA’s and Pennsylvania’s records show in this utility’s water: PFAS; nitrate, arsenic and other regulated chemicals; and violations since 2016, with the certification that handles each result.
- Serves
- 125 people
- Connections
- 1
- Water source
- Groundwater
- Based in
- Moscow, PA
- County
- Pike
- Owner
- Private
The short answer
1 result is above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
PFAS: Pennsylvania’s own results under its PFAS rule, entry point samples taken from Feb. 25, 2025 to Dec. 9, 2025.
Arsenic, nitrate, chromium (total), fluoride and uranium: Pennsylvania’s own results, samples taken from March 24, 2020 to Nov. 4, 2025.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples.
EPA’s 2024 PFAS rule, compound by compound
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 8 samples |
| PFOS | 4.0 ppt | Not foundNot found in any of 8 samples |
| PFHxS | 10 ppt | Not foundNot found in any of 8 samples |
| PFNA | 10 ppt | Not foundNot found in any of 8 samples |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 8 samples |
| PFBS | Index only | Not foundNot found in any of 8 samples |
| Results from Pennsylvania’s own PFAS monitoring, samples where water enters the pipes; each compound’s card has its four-quarter averages, the way limits are judged. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. Pennsylvania’s own limits for PFOA and PFOS are in force now. PFBS has no limit of its own and counts only toward EPA’s Hazard Index, which TapBuff works out only from UCMR 5’s averages, so it isn’t given here. | ||
Above the health goal1
Arsenic
Comes from the source
0.55ppb
Highest yearly average, 2024
Averaged by year, the highest was 0.55 ppb, in 2024: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 1.1 ppb. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits1
Nitrate
Comes from the source
1.2ppm
Highest sample; found in 4 of 4
2025 average: 0.79 ppm
The highest sample, in 2025, was 1.2 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its two samples averaged 0.79 ppm.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
9 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
- Fluoride
- Uranium
PFAS, from Pennsylvania’s own monitoring
- HFPO-DA (GenX)
- PFBS
- PFHxS
- PFNA
- PFOA
- PFOS
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2,537 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Arsenic, nitrate, chromium (total), fluoride and uranium results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Sunrise Lakes Sec 12’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from March 24, 2020 to Nov. 4, 2025; Pennsylvania’s PFAS results run from Feb. 25, 2025 to Dec. 9, 2025.
Testing your own tap
No lab Pennsylvania certifies is within 75 miles of the area Sunrise Lakes Sec 12 serves on the state’s list. Some take samples by mail; the state’s page lists them all.
Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.
All 108 certified labs for PennsylvaniaSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- Pennsylvania Department of Environmental Protection, Drinking Water Reporting System, PFAS results read Oct. 17, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Pennsylvania Department of Environmental Protection, Drinking Water Reporting System, results from Jan. 2, 2020 to Oct. 8, 2026, read Oct. 17, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID PA2520092. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on ArsenicWhat each one does to health, where it comes from, and the certification claim that addresses it.About Arsenic
- Get the utility’s own reportSunrise Lakes Sec 12 must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs