What EPA’s and Pennsylvania’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
204 people
Connections
74
Water source
Surface water bought from another system
Based in
Harrisburg, PA
County
Franklin
Owner
Private
The ZIP code it serves

17201

The short answer

1 result is above EPA’s legal limit, and 1 more is above the limit’s level with no violation recorded. The worst: Lead, above the action level. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1996 to 1998.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic, chromium (total), nitrate and uranium: Pennsylvania’s own results, samples taken from Aug. 5, 2020 to Sept. 10, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Lead

Comes from pipes, often your own

Above the action level

71ppb

90th percentile, 1998

In the latest period, 9 in 10 homes sampled were at or below 71 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Above the limit’s level, no violation recorded1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the limit’s level, no violation

83.2ppb

Highest yearly average, 2021 to 2026

Averaged by year, the highest was 83.2 ppb, in 2026, above EPA’s legal limit of 80 ppb. That was also the latest year on file. EPA judges this limit on running averages at each sampling point, and recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 8.0 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits2

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

19.9ppb

Highest yearly average, 2021 to 2026

Averaged by year, the highest was 19.9 ppb, in 2026, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.0 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.3ppm

Highest yearly average, 2021

Averaged by year, the highest was 0.3 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.3 ppm, in 2012.

What handles it

4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Nitrate
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Trihalomethanes (TTHM) Reduction

    For: Lead, Total trihalomethanes (TTHM)

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claims: Lead Reduction, Trihalomethanes (TTHM) Reduction

    For: Lead, Total trihalomethanes (TTHM)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 49 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic, chromium (total), nitrate and uranium results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Suez Water Kensington System’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from Aug. 5, 2020 to Sept. 10, 2026.

Testing your own tap

Suez Water Kensington System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

The 3 labs Pennsylvania certifies closest to the area Suez Water Kensington System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SPL-Chambersburg

    Chambersburg, PA · under a mile

    Certified for bacteria

    (717) 263-9970

  • Laboratory, Analytical and Biological Services, Inc

    New Oxford, PA · about 31 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (717) 259-6550

  • H2O Environmental LLC

    Harrisburg, PA · about 51 miles

    Certified for bacteria

    (717) 743-9310

Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.

All 108 certified labs for Pennsylvania

Sources