Skip to content
TapBuff

Saegertown Borough

What EPA’s and Pennsylvania’s records show in this utility’s water: PFAS; nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,500 people
Connections
388
Water source
Groundwater
Based in
Saegertown, PA
County
Crawford
Owner
Local government
The ZIP code it serves

16433

The short answer

1 result is above EPA’s legal limit, 2 more are above EPA’s new limit, which takes effect in 2029, and 2 more are above the health goal. The worst: PFOS, above Pennsylvania’s limit. No health-based violations on file since 2016.

What handles it

What was found

PFAS: Pennsylvania’s own results under its PFAS rule, entry point samples taken from Feb. 7, 2023 to Aug. 6, 2026.

Lead and copper: EPA SDWIS monitoring periods ending 1993 to 1996.

Arsenic, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), chromium (total), fluoride and uranium: Pennsylvania’s own results, samples taken from July 7, 2020 to Sept. 15, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: PFOS, PFHxS, PFOA, PFNA and PFBS were found, of the six PFAS in EPA’s 2024 drinking water rule; their results are below. Two other PFAS with no federal limit were found, the highest PFHxA at 8.9 ppt: see them below.

EPA’s 2024 PFAS rule, compound by compound

PFASEPA’s limitResult
PFOA4.0 pptAbove EPA’s new limit (2029)6.2 ppt highest, found in 16 of 49 samples. Details
PFOS4.0 pptAbove Pennsylvania’s limit275 ppt highest, found in 30 of 51 samples. Details
PFHxS10 pptAbove EPA’s new limit (2029)91.1 ppt highest, found in 25 of 47 samples. Details
PFNA10 pptBelow EPA’s limits3.1 ppt highest, found in 6 of 46 samples. Details
HFPO-DA (GenX)10 pptNot foundNot found in any of 45 samples
PFBSIndex onlyBelow EPA’s limits7.6 ppt highest, found in 10 of 47 samples. Details
Results from Pennsylvania’s own PFAS monitoring, samples where water enters the pipes; each compound’s card has its four-quarter averages, the way limits are judged. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. Pennsylvania’s own limits for PFOA and PFOS are in force now. PFBS has no limit of its own and counts only toward EPA’s Hazard Index, which TapBuff works out only from UCMR 5’s averages, so it isn’t given here.

About PFAS certifications

NSF’s PFAS claims are tested to below 20 ppt. EPA’s limit is 4.0 ppt, and EPA says no certification yet shows a filter reaching its levels.

Above the legal limit1

PFOS

Comes from the source

Above Pennsylvania’s limit

275ppt

Highest sample, July 1, 2025; found in 30 of 51

2026 average: 29.9 ppt

The highest sample was 275 ppt, about 69 times EPA’s new limit of 4.0 ppt, which takes effect in 2029. EPA’s health goal is zero. Compliance will be judged on a running annual average, not one sample. Averaged over four quarters at one entry point, the way both Pennsylvania’s limit and EPA’s are judged, the highest was 214 ppt, for the year to March 31, 2026: above Pennsylvania’s limit of 18 ppt and above EPA’s new limit of 4.0 ppt. Pennsylvania recorded 11 violations of its limit for PFOS here, dated July 23, 2024, Oct. 22, 2024, Feb. 10, 2025 and 6 more dates, on running averages of 19 to 239 ppt. In 2026, the latest year on file, its nine samples averaged 29.9 ppt.

What handles it

Above EPA’s new limit, which takes effect in 20292

PFHxS

Comes from the source

Above EPA’s new limit (2029)

91.1ppt

Highest sample, Oct. 1, 2024; found in 25 of 47

2026 average: 9.9 ppt

The highest sample was 91.1 ppt, about 9.1 times EPA’s new limit of 10 ppt, which takes effect in 2029. EPA’s health goal is 10 ppt. Compliance will be judged on a running annual average, not one sample. Averaged over four quarters at one entry point, the way EPA’s limit is judged, the highest was 57.1 ppt, for the year to March 31, 2025: above EPA’s new limit of 10 ppt. In 2026, the latest year on file, its nine samples averaged 9.9 ppt.

What handles it

PFOA

Comes from the source

Above EPA’s new limit (2029)

6.2ppt

Highest sample, June 5, 2024; found in 16 of 49

2026 average: 0.63 ppt

The highest sample was 6.2 ppt, above EPA’s new limit of 4.0 ppt, which takes effect in 2029. EPA’s health goal is zero. Compliance will be judged on a running annual average, not one sample. Averaged over four quarters at one entry point, the way both Pennsylvania’s limit and EPA’s are judged, the highest was 4.8 ppt, for the year to Sept. 30, 2025: below Pennsylvania’s limit of 14 ppt and above EPA’s new limit of 4.0 ppt. In 2026, the latest year on file, its nine samples averaged 0.63 ppt.

What handles it

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

5.0ppb

90th percentile, 1996

In the latest period, 9 in 10 homes sampled were at or below 5.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

2.2ppb

Highest yearly average, 2021 to 2024

2024 average: 1.5 ppb

Averaged by year, the highest was 2.2 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 5.0 ppb. In 2024, the latest year on file, its six samples averaged 1.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.4 ppb, in 2018.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits6

PFNA

Comes from the source

Below EPA’s limits

3.1ppt

Highest sample, Oct. 7, 2025; found in 6 of 46

2026 average: 0.32 ppt

The highest sample was 3.1 ppt, below EPA’s new limit of 10 ppt, which takes effect in 2029. Averaged over four quarters at one entry point, the way EPA’s limit is judged, the highest was 1.5 ppt, for the year to March 31, 2025: below EPA’s new limit of 10 ppt. In 2026, the latest year on file, its nine samples averaged 0.32 ppt.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

16.6ppb

Highest yearly average, 2020 to 2026

2026 average: 10 ppb

Averaged by year, the highest was 16.6 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 28.4 ppb. In 2026, the latest year on file, its two samples averaged 10 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 19 ppb, in 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

1.9ppm

Highest sample; found in 20 of 40

2026 average: 0.81 ppm

The highest sample, in 2025, was 1.9 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its four samples averaged 0.81 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.7 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.9ppb

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 1.9 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 3.7 ppb. In 2026, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.5 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

Chromium (total)

Comes from the source

Below EPA’s limits

1.7ppb

Highest yearly average, 2021 to 2024

2024: not found

Averaged by year, the highest was 1.7 ppb, in 2021, below EPA’s legal limit of 100 ppb. Its highest single sample was 4.0 ppb. In 2024, the latest year on file, it wasn’t found in any of its six samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.6 ppb, in 2018.

What handles it

PFBS

Comes from the source

Below EPA’s limits

7.6ppt

Highest sample, Oct. 1, 2024; found in 10 of 47

2026 average: 0.57 ppt

The highest sample was 7.6 ppt, below EPA’s hazard index benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own. In 2026, the latest year on file, its nine samples averaged 0.57 ppt.

What handles it

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

CompoundHighest sampleFound inCertification claim
PFHxA8.9 ppt19 of 46None covers it
PFHpA2.9 ppt8 of 46NSF/ANSI 53: Total PFAS Reduction
13 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Fluoride
  • Uranium

PFAS, from Pennsylvania’s own monitoring

  • 11Cl-PF3OUdS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NMeFOSAA
  • PFDA
  • PFDoA
  • PFTA
  • PFTrDA
  • PFUnA

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: PFOS Reduction, Total PFAS Reduction, PFOA Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: PFOS, PFHxS, PFOA, Lead, Arsenic

    Other certifiers’ wording: Perfluorooctane Sulfonate (PFOS); Perfluorohexane Sulfonic Acid (PFHxS); Perfluorooctanoic Acid (PFOA); Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Perfluorooctane Sulfonate (PFOS), Perfluorooctanoic Acid (PFOA), Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: PFOS, PFOA, Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for PFAS, ranked

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 127 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), chromium (total), fluoride and uranium results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Saegertown Borough’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from July 7, 2020 to Sept. 15, 2026; Pennsylvania’s PFAS results run from Feb. 7, 2023 to Aug. 6, 2026.

Testing your own tap

Saegertown Borough’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

The 3 labs Pennsylvania certifies closest to the area Saegertown Borough serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Presque Isle Water Testing

    Erie, PA · about 22 miles

    Certified for bacteria, nitrate

    (814) 636-0555

  • Free-Col Laboratory

    Erie, PA · about 27 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (814) 460-0861

  • Microbac Laboratories, Inc - Erie Division

    Erie, PA · about 27 miles

    Certified for bacteria

    (814) 825-8533

Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.

All 108 certified labs for Pennsylvania

Sources

PWSID PA6200043. Rebuilt from EPA data on Oct. 18, 2026.