Skip to content
TapBuff

Laurel Lane Development Assoc

What EPA’s and Pennsylvania’s records show in this utility’s water: PFAS; nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
179 people
Connections
90
Water source
Groundwater
Based in
Greentown, PA
County
Pike
Owner
Private
The ZIP code it serves

18426

The short answer

1 result is above EPA’s legal limit. The worst: Lead, above the action level. 8 health-based violations since 2016.

What handles it

What was found

PFAS: Pennsylvania’s own results under its PFAS rule, entry point samples taken from Feb. 20, 2025 to Oct. 8, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 1995 to 2017.

Nitrate, chromium (total), fluoride, arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium: Pennsylvania’s own results, samples taken from May 11, 2020 to Oct. 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 12 PFAS tested for was found either.

EPA’s 2024 PFAS rule, compound by compound

PFASEPA’s limitResult
PFOA4.0 pptNot foundNot found in any of 12 samples
PFOS4.0 pptNot foundNot found in any of 12 samples
PFHxS10 pptNot foundNot found in any of 12 samples
PFNA10 pptNot foundNot found in any of 12 samples
HFPO-DA (GenX)10 pptNot foundNot found in any of 12 samples
PFBSIndex onlyNot foundNot found in any of 12 samples
Results from Pennsylvania’s own PFAS monitoring, samples where water enters the pipes; each compound’s card has its four-quarter averages, the way limits are judged. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. Pennsylvania’s own limits for PFOA and PFOS are in force now. PFBS has no limit of its own and counts only toward EPA’s Hazard Index, which TapBuff works out only from UCMR 5’s averages, so it isn’t given here.

Above the legal limit1

Lead

Comes from pipes, often your own

Above the action level

23ppb

90th percentile, 2017

In the latest period, 9 in 10 homes sampled were at or below 23 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

1.7ppm

Highest sample; found in 18 of 18

2025 average: 1.4 ppm

The highest sample, in 2021, was 1.7 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its three samples averaged 1.4 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.3 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Chromium (total)

Comes from the source

Below EPA’s limits

0.8ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.8 ppb, in 2024, below EPA’s legal limit of 100 ppb. Its highest single sample was 1.2 ppb. That was also the latest year on file.

What handles it

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.02ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.02 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.06 ppm. That was also the latest year on file.

What handles it

22 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Haloacetic acids (HAA5)
  • Total trihalomethanes (TTHM)
  • Uranium

PFAS, from Pennsylvania’s own monitoring

  • 11Cl-PF3OUdS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFHpA
  • PFHxA
  • PFHxS
  • PFNA
  • PFOA
  • PFOS
  • PFTA
  • PFTrDA
  • PFUnA

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)Jan. 1, 2025 to Jan. 31, 2025—Resolved
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)Feb. 1, 2024 to Feb. 29, 2024—Resolved
Lead and Copper RuleOCCT/SOWT Treatment Installation/DemonstrationSept. 26, 2021—Resolved
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationApril 1, 2019—Resolved
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)March 1, 2019 to March 31, 2019—Resolved
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)May 1, 2018 to May 31, 2018—Resolved
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)March 1, 2018 to March 31, 2018—Resolved
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)July 1, 2016 to July 31, 2016—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 36 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, chromium (total), fluoride, arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Laurel Lane Development Assoc’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from May 11, 2020 to Oct. 8, 2025; Pennsylvania’s PFAS results run from Feb. 20, 2025 to Oct. 8, 2025.

Testing your own tap

Laurel Lane Development Assoc’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

The 3 labs Pennsylvania certifies closest to the area Laurel Lane Development Assoc serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Princeton Analytical Labs

    Dunmore, PA · about 22 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (570) 209-7916

  • Microbac Laboratories, Inc. - Pittston

    Pittston, PA · about 26 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (570) 348-0775

  • A E Kirby Memorial Health Center

    Wilkes-Barre, PA · about 34 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (570) 822-4278

Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.

All 108 certified labs for Pennsylvania

Sources

PWSID PA2520201. Rebuilt from EPA data on Oct. 18, 2026.