Skip to content
TapBuff

Bcwsa New Hope

What EPA’s and Pennsylvania’s records show in this utility’s water: PFAS; nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
3,017 people
Connections
3,017
Water source
Surface water
Based in
Warrington, PA
County
Bucks
Owner
Local government
The ZIP code it serves

18938

The short answer

1 result is above EPA’s legal limit, 1 more is above EPA’s new limit, which takes effect in 2029, and 3 more are above the health goal. The worst: PFOS, above Pennsylvania’s limit. No health-based violations on file since 2016.

What handles it

What was found

PFAS: Pennsylvania’s own results under its PFAS rule, entry point samples taken from July 28, 2023 to Sept. 24, 2026.

Lead and copper: EPA SDWIS monitoring periods ending 1993 to 1996.

Arsenic, uranium, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), chromium (total) and fluoride: Pennsylvania’s own results, samples taken from March 9, 2020 to Aug. 10, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: PFOS, PFOA, PFHxS, PFNA and PFBS were found, of the six PFAS in EPA’s 2024 drinking water rule; their results are below. Two other PFAS with no federal limit were found, the highest PFHxA at 4.4 ppt: see them below.

EPA’s 2024 PFAS rule, compound by compound

PFASEPA’s limitResult
PFOA4.0 pptAbove EPA’s new limit (2029)11 ppt highest, found in 29 of 36 samples. Details
PFOS4.0 pptAbove Pennsylvania’s limit22 ppt highest, found in 31 of 36 samples. Details
PFHxS10 pptBelow EPA’s limits8.1 ppt highest, found in 9 of 30 samples. Details
PFNA10 pptBelow EPA’s limits5.5 ppt highest, found in 8 of 30 samples. Details
HFPO-DA (GenX)10 pptNot foundNot found in any of 30 samples
PFBSIndex onlyBelow EPA’s limits6.3 ppt highest, found in 17 of 30 samples. Details
Results from Pennsylvania’s own PFAS monitoring, samples where water enters the pipes; each compound’s card has its four-quarter averages, the way limits are judged. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. Pennsylvania’s own limits for PFOA and PFOS are in force now. PFBS has no limit of its own and counts only toward EPA’s Hazard Index, which TapBuff works out only from UCMR 5’s averages, so it isn’t given here.

About PFAS certifications

NSF’s PFAS claims are tested to below 20 ppt. EPA’s limit is 4.0 ppt, and EPA says no certification yet shows a filter reaching its levels.

Above the legal limit1

PFOS

Comes from the source

Above Pennsylvania’s limit

22ppt

Highest sample, Feb. 6, 2024; found in 31 of 36

2026 average: 2.0 ppt

The highest sample was 22 ppt, about 5.5 times EPA’s new limit of 4.0 ppt, which takes effect in 2029. EPA’s health goal is zero. Compliance will be judged on a running annual average, not one sample. Averaged over four quarters at one entry point, the way both Pennsylvania’s limit and EPA’s are judged, the highest was 17.8 ppt, for the year to Dec. 31, 2024: below Pennsylvania’s limit of 18 ppt and above EPA’s new limit of 4.0 ppt. Pennsylvania recorded two violations of its limit for PFOS here, dated July 31, 2024 and Nov. 12, 2024, on running averages of 19 to 21 ppt. In 2026, the latest year on file, its nine samples averaged 2.0 ppt.

What handles it

Above EPA’s new limit, which takes effect in 20291

PFOA

Comes from the source

Above EPA’s new limit (2029)

11ppt

Highest sample, Oct. 22, 2024; found in 29 of 36

2026 average: 2.9 ppt

The highest sample was 11 ppt, about 2.8 times EPA’s new limit of 4.0 ppt, which takes effect in 2029. EPA’s health goal is zero. Compliance will be judged on a running annual average, not one sample. Averaged over four quarters at one entry point, the way both Pennsylvania’s limit and EPA’s are judged, the highest was 10.3 ppt, for the year to March 31, 2025: below Pennsylvania’s limit of 14 ppt and above EPA’s new limit of 4.0 ppt. In 2026, the latest year on file, its nine samples averaged 2.9 ppt.

What handles it

Above the health goal3

Arsenic

Comes from the source

Above the health goal

3.0ppb

Highest yearly average, 2020 to 2026

2026 average: 2.5 ppb

Averaged by year, the highest was 3.0 ppb, in 2020: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 5.0 ppb. In 2026, the latest year on file, its two samples averaged 2.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.5 ppb, in 2017.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

5.2ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 5.2 ppb, in 2025: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 10.4 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.8 ppb, in 2019.

What handles it

Lead

Comes from pipes, often your own

Above the health goal

1.0ppb

90th percentile, 1996

In the latest period, 9 in 10 homes sampled were at or below 1.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits6

PFHxS

Comes from the source

Below EPA’s limits

8.1ppt

Highest sample, Aug. 14, 2023; found in 9 of 30

2026: not found

The highest sample was 8.1 ppt, below EPA’s new limit of 10 ppt, which takes effect in 2029. Averaged over four quarters at one entry point, the way EPA’s limit is judged, the highest was 6.6 ppt, for the year to Sept. 30, 2025: below EPA’s new limit of 10 ppt. In 2026, the latest year on file, it wasn’t found in any of its nine samples.

What handles it

PFNA

Comes from the source

Below EPA’s limits

5.5ppt

Highest sample, Aug. 14, 2023; found in 8 of 30

2026: not found

The highest sample was 5.5 ppt, below EPA’s new limit of 10 ppt, which takes effect in 2029. Averaged over four quarters at one entry point, the way EPA’s limit is judged, the highest was 5.1 ppt, for the year to Sept. 30, 2025: below EPA’s new limit of 10 ppt. In 2026, the latest year on file, it wasn’t found in any of its nine samples.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

24ppb

Highest yearly average, 2020 to 2026

2026 average: 17 ppb

Averaged by year, the highest was 24 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 59.1 ppb. In 2026, the latest year on file, its six samples averaged 17 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 32.2 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

2.5ppm

Highest sample; found in 15 of 21

2026 average: 0.77 ppm

The highest sample, in 2022, was 2.5 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its three samples averaged 0.77 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.9 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

11.6ppb

Highest yearly average, 2020 to 2026

2026 average: 2.7 ppb

Averaged by year, the highest was 11.6 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 39.9 ppb. In 2026, the latest year on file, its six samples averaged 2.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.5 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

PFBS

Comes from the source

Below EPA’s limits

6.3ppt

Highest sample, April 23, 2025; found in 17 of 30

2026 average: 0.92 ppt

The highest sample was 6.3 ppt, below EPA’s hazard index benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own. In 2026, the latest year on file, its nine samples averaged 0.92 ppt.

What handles it

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

CompoundHighest sampleFound inCertification claim
PFHxA4.4 ppt1 of 2None covers it
PFHpA3.4 ppt1 of 2NSF/ANSI 53: Total PFAS Reduction
13 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)
  • Fluoride

PFAS, from Pennsylvania’s own monitoring

  • 11Cl-PF3OUdS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NMeFOSAA
  • PFDA
  • PFDoA
  • PFTA
  • PFTrDA
  • PFUnA

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: PFOS Reduction, PFOA Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: PFOS, PFOA, Arsenic, Lead

    Other certifiers’ wording: Total PFAS Reduction; Perfluorooctane Sulfonate (PFOS); Perfluorooctanoic Acid (PFOA); Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Perfluorooctane Sulfonate (PFOS), Perfluorooctanoic Acid (PFOA), Arsenic (Pentavalent)<=50 ppb Reduction, Uranium, Lead Reduction

    For: PFOS, PFOA, Arsenic, Uranium, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for PFAS, ranked

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 13 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, uranium, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), chromium (total) and fluoride results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Bcwsa New Hope’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from March 9, 2020 to Aug. 10, 2026; Pennsylvania’s PFAS results run from July 28, 2023 to Sept. 24, 2026.

Testing your own tap

Bcwsa New Hope’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

The 3 labs Pennsylvania certifies closest to the area Bcwsa New Hope serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, LLC - Ewing

    Ewing, NJ · about 11 miles

    Certified for bacteria

    (609) 737-3477

  • Eurofins Philadelphia - Horsham

    Horsham, PA · about 14 miles

    Certified for bacteria

    (215) 355-3900

  • Criterion Laboratories Inc

    Bensalem, PA · about 18 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS

    (215) 244-1300

Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.

All 108 certified labs for Pennsylvania

Sources

PWSID PA1090130. Rebuilt from EPA data on Oct. 18, 2026.