Skip to content
TapBuff

Village of Pleasant City

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
447 people
Connections
320
Water source
Groundwater
Based in
Pleasant City, OH
County
Guernsey
Owner
Local government
The ZIP code it serves

43772

The short answer

1 result is above the limit’s level with no violation recorded, and 1 more is above the health goal. The worst: Arsenic, above the limit’s level, no violation. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2018 to 2025. Copper at 886 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.7 ppm, for the period ending June 30, 2000. None since is on file, so it is not counted as a current finding.

Arsenic, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), fluoride and chromium (total): Ohio’s own results, samples taken from Jan. 7, 2020 to Dec. 9, 2025, with EPA’s 2012 to 2019 file for earlier years.

Above the limit’s level, no violation recorded1

Arsenic

Comes from the source

Above the limit’s level, no violation

36.9ppb

Highest yearly average, 2020 to 2025

2025 average: 19.5 ppb

Averaged by year, the highest was 36.9 ppb, in 2020, about 3.7 times EPA’s legal limit of 10 ppb. Its highest single sample was 114 ppb. In 2025, the latest year on file, its six samples averaged 19.5 ppb, above the limit. EPA judges this limit on running averages at each sampling point, and recorded no violation for arsenic at this utility since 2020. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.9 ppb, in 2013.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

1.0ppb

90th percentile, 2025

In the latest period, 9 in 10 homes sampled were at or below 1.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

40.6ppb

Highest yearly average, 2020 to 2025

2025 average: 25 ppb

Averaged by year, the highest was 40.6 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 88.3 ppb. In 2025, the latest year on file, its eight samples averaged 25 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 97.9 ppb, in 2012, and EPA recorded a violation in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

3.0ppm

Highest sample; found in 6 of 6

2025, one sample: 2.9 ppm

The highest sample, in 2020, was 3.0 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was 2.9 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.6 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

6.2ppb

Highest yearly average, 2020 to 2025

2025 average: 3.1 ppb

Averaged by year, the highest was 6.2 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 18.7 ppb. In 2025, the latest year on file, its eight samples averaged 3.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 20 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.27ppm

Highest yearly average, 2020 to 2023

Averaged by year, the highest was 0.27 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.26 ppm, in 2017.

What handles it

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

No health-based violations on file with EPA since 2016.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), fluoride and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Village of Pleasant City’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Jan. 7, 2020 to Dec. 9, 2025.

Testing your own tap

Village of Pleasant City’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Village of Pleasant City serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SafeSource Water Analytics LLC

    McConnelsville, OH · about 20 miles

    Certified for bacteria, nitrate

    (740) 292-2002

  • Microbac Laboratories, Inc. - Marietta Division

    Marietta, OH · about 32 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, PFAS

    (740) 373-4071

  • Coshocton Environmental Testing, LLC

    Coshocton, OH · about 32 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (740) 622-3328

All 76 certified labs for Ohio

Sources