Skip to content
TapBuff

Quaker City

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
750 people
Connections
325
Water source
Surface water bought from another system
Based in
Quaker City, OH
County
Guernsey
Owner
Local government
The ZIP code it serves

43773

The short answer

Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): Ohio’s own results, samples taken from Jan. 2, 2020 to Oct. 1, 2025, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits2

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

35.4ppb

Highest yearly average, 2020 to 2025

2025 average: 22.1 ppb

Averaged by year, the highest was 35.4 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 52.7 ppb. In 2025, the latest year on file, its eight samples averaged 22.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 36.6 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

45.9ppb

Highest yearly average, 2020 to 2025

2025 average: 40.9 ppb

Averaged by year, the highest was 45.9 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 71.7 ppb. In 2025, the latest year on file, its eight samples averaged 40.9 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 50.8 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

Violations since 2016

No health-based violations on file with EPA since 2016. There are 5 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Quaker City’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Jan. 2, 2020 to Oct. 1, 2025.

Testing your own tap

Quaker City’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Quaker City serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SafeSource Water Analytics LLC

    McConnelsville, OH · about 33 miles

    Certified for bacteria, nitrate

    (740) 292-2002

  • Coshocton Environmental Testing, LLC

    Coshocton, OH · about 36 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (740) 622-3328

  • Microbac Laboratories, Inc. - Marietta Division

    Marietta, OH · about 39 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, PFAS

    (740) 373-4071

All 76 certified labs for Ohio

Sources

PWSID OH3001011. Rebuilt from EPA data on Oct. 18, 2026.