Skip to content
TapBuff

Towbridge Development

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
352 people
Connections
87
Water source
Groundwater
Based in
Hudson, OH
County
Summit
Owner
Private
Hardness
Very hard
The ZIP code it serves

44236

The short answer

Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Lead and copper: copper at 125 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Total trihalomethanes (TTHM), nitrate, arsenic, chromium (total), fluoride and haloacetic acids (HAA5): Ohio’s own results, samples taken from Jan. 6, 2020 to Oct. 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits2

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

4.3ppb

Highest yearly average, 2020 to 2025

2025, one sample: 3.4 ppb

Averaged by year, the highest was 4.3 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 4.3 ppb. In 2025, the latest year on file, its one sample was 3.4 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.2 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.09ppm

Highest sample; found in 4 of 6

2025: not found

The highest sample, in 2022, was 0.09 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.14 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Fluoride
  • Haloacetic acids (HAA5)
  • Lead

Hardness

Very hard, 338 mg/L (19.8 grains per gallon), at its one sampling point, in 2021.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), nitrate, arsenic, chromium (total), fluoride and haloacetic acids (HAA5) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Towbridge Development’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Jan. 6, 2020 to Oct. 8, 2025.

Testing your own tap

Towbridge Development’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Towbridge Development serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • EnviroScience

    Stow, OH · about 5 miles

    (330) 688-0111

  • Alliance Technical Group, LLC-Akron

    Cuyahoga Falls, OH · about 7 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity

    (330) 253-8211

  • Biosolutions, LLC

    Chagrin Falls, OH · about 13 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (440) 708-2999

All 76 certified labs for Ohio

Sources

PWSID OH7708112. Rebuilt from EPA data on Oct. 18, 2026.