Skip to content
TapBuff

Town of Candor

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
875 people
Connections
351
Water source
Surface water bought from another system
Based in
Candor, NC
County
Montgomery
Owner
Local government
The ZIP code it serves

27229

The short answer

2 results are above EPA’s legal limit. The worst: Total trihalomethanes (TTHM), above the legal limit. 8 health-based violations since 2016.

What handles it

What was found

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): North Carolina’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit2

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

70ppb

Highest yearly average, 2020 to 2023

Averaged by year, the highest was 70 ppb, in 2023, below EPA’s legal limit of 80 ppb. That was also the latest year on file. EPA judges this limit at each sampling point, and recorded violations for total trihalomethanes (TTHM) at this utility in 2024 and 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 63.4 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Above the legal limit

42.6ppb

Highest yearly average, 2020 to 2023

2023 average: 33.4 ppb

Averaged by year, the highest was 42.6 ppb, in 2021, below EPA’s legal limit of 60 ppb. In 2023, the latest year on file, it averaged 33.4 ppb. EPA judges this limit at each sampling point, and recorded a violation for haloacetic acids (HAA5) at this utility in 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 49.6 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2025 to Sept. 30, 20250.067 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2025 to Sept. 30, 20250.089 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 20250.062 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 20250.092 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 20250.087 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 20250.061 MG/LResolved
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2024 to Dec. 31, 20240.09 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 9 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are North Carolina’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Town of Candor’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for North Carolina cover 2020 to 2023.

Testing your own tap

Town of Candor’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab North Carolina certifies.

The 3 labs North Carolina certifies closest to the area Town of Candor serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Cameron Testing Services Inc.

    Sanford, NC · about 37 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (919) 208-4240

  • Tri State Water Systems

    Randleman, NC · about 40 miles

    Certified for bacteria

    (336) 706-0747

  • K & W Laboratories, LLC

    Midland, NC · about 42 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (704) 888-1211

All 112 certified labs for North Carolina

Sources

PWSID NC0362030. Rebuilt from EPA data on Oct. 18, 2026.