Skip to content
TapBuff

Pine Ridge Estates

What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
175 people
Connections
89
Water source
Groundwater
Based in
Coeymans (T), NY
County
Albany
Owner
Private

The short answer

1 result is above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2023.

Total trihalomethanes (TTHM), nitrate, arsenic and haloacetic acids (HAA5): New York’s yearly summaries per water system, 2021 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Feb. 28, 2013 to June 4, 2019. Newer results are in the utility’s annual water quality report.

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

3.5ppb

90th percentile, 2021 to 2023

In the latest period, 9 in 10 homes sampled were at or below 3.5 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.3ppm

Highest yearly average, 2013 to 2019

2019, one sample: 0.3 ppm

Averaged by year, the highest was 0.3 ppm, in 2013, below EPA’s legal limit of 4.0 ppm. In 2019, the latest year on file, its one sample was 0.3 ppm.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

3.0ppb

Highest yearly average, 2022

Averaged by year, the highest was 3.0 ppb, in 2022, below EPA’s legal limit of 80 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.2 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.11ppm

Highest sample; found in 1 of 4

2024: not found

The highest sample, in 2021, was 0.11 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, it wasn’t found.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Haloacetic acids (HAA5)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 7 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), nitrate, arsenic and haloacetic acids (HAA5) results here are New York’s own yearly summaries from 2021 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Pine Ridge Estates’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2021 to 2024; EPA’s compliance samples are from Feb. 28, 2013 to June 4, 2019.

Testing your own tap

Pine Ridge Estates’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

No lab New York certifies is within 75 miles of the area Pine Ridge Estates serves on the state’s list. Some take samples by mail; the state’s page lists them all.

All 161 certified labs for New York

Sources

PWSID NY0101649. Rebuilt from EPA data on Oct. 18, 2026.