Skip to content
TapBuff

Latham Water District

EPA’s and New York’s records have results for 38 contaminants in its water; 5 were found.

Serves 85,590 people · Surface water · Colonie (T), NY

Serves
85,590 people
Connections
19,750
Water source
Surface water
Based in
Colonie (T), NY
County
Albany
Owner
Local government
The 9 ZIP codes it serves

12047, 12110, 12128, 12189, 12204, 12205, 12211, 12304, 12309

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

Filters for lead and uranium, if you want them lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 10 to Oct. 4, 2023.

Lead and copper: EPA SDWIS monitoring periods ending 2006 to 2024.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, uranium and arsenic: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Chromium (total) and fluoride: EPA’s compliance monitoring file, samples taken from Oct. 3, 2012 to Oct. 2, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 5 results

Lead and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 41.6 ppb

Highest yearly average, 2020 to 2024 · 2024 average: 27.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 41.6 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 75.8 ppb. In 2024, the latest year on file, it averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 33.4 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 54.6 ppb

Highest yearly average, 2020 to 2024 · Forms or is added in treatment

Averaged by year, the highest was 54.6 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 93.1 ppb. That was also the latest year on file. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 52 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.0 ppb

90th percentile, 2024 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.73 ppm

Highest sample; found in 4 of 5 · 2024 average: 0.73 ppm · Comes from the source

The highest sample, in 2024, was 0.73 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and it averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.7 ppm, in 2016.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 0.012 ppb

Highest yearly average, 2023 · Comes from the source

Averaged by year, the highest was 0.012 ppb, in 2023, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.023 ppb, in 2017.

What handles it

About uranium
New York utilities above EPA’s PFAS limits⁠
33 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Fluoride

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best water filters for lead, ranked⁠

Disinfectant

Latham Water District reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 sampling for EPA. It also reported chlorine dioxide.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, uranium and arsenic results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total) and fluoride come from EPA’s file alone, which ends in 2019. Latham Water District’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 10 to Oct. 4, 2023; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from Oct. 3, 2012 to Oct. 2, 2019.

Testing your own tap

Latham Water District’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Latham Water District’s latest lead sampling in EPA’s records, 2024, had a 90th percentile of 2.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs New York certifies closest to the area Latham Water District serves, or a kit by mail

The 3 labs New York certifies closest to the area Latham Water District serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Jh Consulting Group, Inc.

    Loudonville, NY · about 3 miles

    Certified for bacteria, nitrate

    (518) 785-9839

  • NYS DOH Environmental Biology Laboratory

    Albany, NY · about 5 miles

    Certified for bacteria

    (518) 474-7161

  • NYS DOH Inorganic & Nuclear Chemistry Laboratory

    Albany, NY · about 5 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, radioactivity, asbestos

    (518) 474-7161

All 161 certified labs for New York⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that New York certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against New York’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID NY0100198. Rebuilt from EPA data on Oct. 25, 2026.