Skip to content
TapBuff

Perry Village

EPA’s and New York’s records have results for 38 contaminants in its water; 7 were found.

Serves 3,673 people · Surface water · Perry (T), NY

Serves
3,673 people
Connections
1,666
Water source
Surface water
Based in
Perry (T), NY
County
Wyoming
Owner
Local government
The 2 ZIP codes it serves

14427, 14530

The short answer

Total trihalomethanes (TTHM) averaged above its legal limit’s level in 2021, with no violation recorded. No health-based violations on file since 2016.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 17 to Dec. 9, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2025.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic and nitrate: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Fluoride, chromium (total) and uranium: EPA’s compliance monitoring file, samples taken from Jan. 30, 2012 to Dec. 11, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Above the limit’s level, no violation recorded, 1 result

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the limit’s level, no violation

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A filter certified for it, at the tap you drink from, reduces it.

83.5 ppb

Highest yearly average, 2020 to 2024

2024 average: 50.8 ppb

Averaged by year, the highest was 83.5 ppb, in 2021, above EPA’s legal limit of 80 ppb. Its highest single sample was 228 ppb. In 2024, the latest year on file, it averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

How it’s judged

EPA judges this limit on running averages at each sampling point. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 78.5 ppb, in 2014, and EPA recorded a violation in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits, 6 results

Arsenic and lead have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 35.9 ppb

Highest yearly average, 2020 to 2024 · 2024 average: 25.9 ppb · Forms or is added in treatment

Averaged by year, the highest was 35.9 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 62.9 ppb. In 2024, the latest year on file, it averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 42.5 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.74 ppm

Highest yearly average, 2012 to 2019 · 2019 average: 0.72 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.74 ppm, in 2014, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 2.0 ppm. In 2019, the latest year on file, its two samples averaged below the limit.

What handles it

About fluoride
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 1.0 ppb

Highest yearly average, 2020 to 2024 · 2024 average: 0.55 ppb · Comes from the source

Averaged by year, the highest was 1.0 ppb, in 2020, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2024, the latest year on file, it averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 1.8 ppb, in 2015.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Nitrate, Legal limit 10 ppm; highest 0.74 ppm

Highest sample; found in 6 of 6 · 2024 average: 0.32 ppm · Comes from the source

The highest sample, in 2020, was 0.74 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, it averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.85 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Lead, Action level 15 ppb · health goal zero; 90th percentile 0.37 ppb

90th percentile, 2023 to 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 0.37 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Chromium (total), Legal limit 100 ppb; highest yearly average 2.0 ppb

Highest yearly average, 2012 to 2019 · Comes from the source

Averaged by year, the highest was 2.0 ppb, in 2019, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

About chromium (total)
New York utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Arsenic, Lead

    Other claims that cover it: VOC Reduction; Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Arsenic, Lead

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for TTHM, ranked⁠

The best reverse osmosis systems, ranked⁠

The best water filters for lead, ranked⁠

Disinfectant

Perry Village reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 34 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic and nitrate results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride, chromium (total) and uranium come from EPA’s file alone, which ends in 2019. Perry Village’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 17 to Dec. 9, 2025; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from Jan. 30, 2012 to Dec. 11, 2019.

Testing your own tap

Perry Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Perry Village’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0.37 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Perry Village’s results flag: total trihalomethanes (TTHM). It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs New York certifies closest to the area Perry Village serves, or a kit by mail

The 3 labs New York certifies closest to the area Perry Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Life Science Laboratories Inc. - Finger Lakes

    Wayland, NY · about 25 miles

    Certified for bacteria

    (585) 213-4090

  • Allegany County Community Environmental Laboratory

    Belmont, NY · about 30 miles

    Certified for bacteria

    (585) 268-9250

  • ALS Environmental - Rochester

    Rochester, NY · about 34 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (585) 288-5380

All 161 certified labs for New York⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that New York certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against New York’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID NY6000613. Rebuilt from EPA data on Oct. 25, 2026.