Skip to content
TapBuff

Attica Correctional

What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,000 people
Connections
1
Water source
Surface water bought from another system
Based in
Attica (T), NY
County
Wyoming
Owner
State government
The ZIP code it serves

14011

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Haloacetic acids (HAA5), above the legal limit. 3 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2006.

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Haloacetic acids (HAA5)

Forms or is added in treatment

Above the legal limit

61ppb

Highest yearly average, 2020 to 2024

2024 average: 48.1 ppb

Averaged by year, the highest was 61 ppb, in 2020, above EPA’s legal limit of 60 ppb. Its highest single sample was 81 ppb. In 2024, the latest year on file, it averaged 48.1 ppb. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 53.3 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

11ppb

90th percentile, 2006

In the latest period, 9 in 10 homes sampled were at or below 11 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

69.9ppb

Highest yearly average, 2020 to 2024

2024 average: 55.9 ppb

Averaged by year, the highest was 69.9 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 113 ppb. In 2024, the latest year on file, it averaged 55.9 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 67.5 ppb, in 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Stage 1 Disinfectants and Disinfection Byproducts RuleTreatment was not run by a certified operator as required.EPA: Treatment Technique No Certif. OperatorJan. 1, 2026—Unaddressed
Stage 1 Disinfectants and Disinfection Byproducts RuleTreatment was not run by a certified operator as required.EPA: Treatment Technique No Certif. OperatorDec. 1, 2023—Resolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 202061 UG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 11 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Attica Correctional’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2020 to 2024.

Testing your own tap

Attica Correctional’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

The 3 labs New York certifies closest to the area Attica Correctional serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • EMSL Analytical Inc.

    Depew, NY · about 21 miles

    Certified for bacteria, asbestos

    (716) 651-0030

  • Mcandrew Laboratory Inc.

    Orchard Park, NY · about 23 miles

    Certified for bacteria

    (716) 649-7960

  • Biotrax Testing Laboratory

    Cheektowaga, NY · about 27 miles

    Certified for bacteria

    (716) 651-0146

All 161 certified labs for New York

Sources