Skip to content
TapBuff

Western Region Allegany Distrib. System

EPA’s and Maryland’s records have results for 32 contaminants in its water; 2 were found.

Serves 4,955 people · Surface water bought from another system · Cumberland, MD

Serves
4,955 people
Connections
1,635
Water source
Surface water bought from another system
Based in
Cumberland, MD
County
Allegany
Owner
Local government
The 4 ZIP codes it serves

21502, 21532, 21543, 21545

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium, plus nitrate, arsenic and other regulated chemicals, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 11 to Dec. 1, 2025.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Maryland’s own results, samples taken from Jan. 8, 2020 to Jan. 28, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 57.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 43.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 57.4 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 101 ppb. In 2026, the latest year on file, its three samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 75.9 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 22.8 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 22.8 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 47.5 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 27.9 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Maryland utilities above EPA’s PFAS limits⁠
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Western Region Allegany Distrib. System reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Maryland’s own from 2020 on, with EPA’s national file for 2012 to 2019. Western Region Allegany Distrib. System’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 11 to Dec. 1, 2025; Maryland’s results run from Jan. 8, 2020 to Jan. 28, 2026.

Testing your own tap

Western Region Allegany Distrib. System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Maryland certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. About lead.
The 3 labs Maryland certifies closest to the area Western Region Allegany Distrib. System serves, or a kit by mail

The 3 labs Maryland certifies closest to the area Western Region Allegany Distrib. System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Geochemical Testing

    Somerset, PA · about 29 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (814) 443-1671

  • Deep Creek Lake Laboratory

    Oakland, MD · about 33 miles

    Certified for bacteria

    (301) 387-6162

  • Pace Analytical Services, LLC - Greensburg

    Greensburg, PA · about 57 miles

    Certified for radioactivity

    (724) 850-5600

All 92 certified labs for Maryland⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Maryland certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Maryland’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID MD0010009. Rebuilt from EPA data on Oct. 25, 2026.