Skip to content
TapBuff

Town of North East

EPA’s and Maryland’s records have results for 37 contaminants in its water; 6 were found.

Serves 8,600 people · Surface water · North East, MD

Serves
8,600 people
Connections
2,709
Water source
Surface water
Based in
North East, MD
County
Cecil
Owner
Local government
The 3 ZIP codes it serves

21901, 21914, 21921

The short answer

EPA recorded violations of the legal limit for haloacetic acids (HAA5) here in four years from 2023 to 2026. EPA recorded a violation of the legal limit for total trihalomethanes (TTHM) here in 2024. In 2026, the latest year on file, it averaged 50 ppb, below the limit. 13 health-based violations since 2016, all resolved in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 13 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Feb. 15, 2023 to Jan. 18, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2023.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total): Maryland’s own results, samples taken from Jan. 13, 2020 to July 8, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 12.5 ppt: see it below.

A legal-limit violation on record, below the limit in the latest year, 2 results

Haloacetic acids (HAA5)

Forms or is added in treatment

Violation on record (2026)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.

69.4 ppb

Highest yearly average, 2020 to 2026

2026 average: 44.4 ppb

Averaged by year, the highest was 69.4 ppb, in 2025, above EPA’s legal limit of 60 ppb. Its highest single sample was 106 ppb. In 2026, the latest year on file, its nine samples averaged below the limit. EPA recorded violations for haloacetic acids (HAA5) at this utility in 2023, 2024, 2025 and 2026.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 49.5 ppb, in 2015, and EPA recorded violations in 2014 and 2015.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Violation on record (2024)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.

75.5 ppb

Highest yearly average, 2020 to 2026

2026 average: 50 ppb

Averaged by year, the highest was 75.5 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 169 ppb. In 2026, the latest year on file, its 11 samples averaged below the limit. EPA recorded a violation for total trihalomethanes (TTHM) at this utility in 2024.

How it’s judged

EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 55.8 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits, 3 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Nitrate, Legal limit 10 ppm; highest 4.7 ppm

Highest sample; found in 10 of 10 · 2026 average: 4.4 ppm · Comes from the source

The highest sample, in 2026, was 4.7 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 4.8 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.61 ppm

Highest yearly average, 2020 to 2026 · 2026 average: 0.39 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.61 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.76 ppm. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.36 ppm, in 2015.

What handles it

About fluoride
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.0 ppb

90th percentile, 2021 to 2023 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Maryland utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFBA12.5 ppt1 of 8None covers it
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other claims that cover it: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for TTHM, ranked⁠

The best water filters for lead, ranked⁠

Disinfectant

Town of North East reported disinfecting with chlorine, not chloramine, at all 2 of its sampling points, in its 2023 to 2024 sampling for EPA. It also reported chlorine dioxide, permanganate and ultraviolet light.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

13 health-based violations since 2016, 6 for total Haloacetic Acids (HAA5), 5 for total organic carbon and 2 for TTHM. The latest began Jan. 1, 2026.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2026 to March 31, 2026, 68 ppbResolved
Oct. 1, 2025 to Dec. 31, 2025, 80 ppbResolved
July 1, 2025 to Sept. 30, 2025, 76 ppbResolved
April 1, 2025 to June 30, 2025, 64 ppbResolved
Total organic carbonNot enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor RemovalJan. 1, 2025 to March 31, 2025, 0.95 RATIOResolved
The other 8, back to 2016
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Total organic carbonNot enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor RemovalOct. 1, 2024 to Dec. 31, 2024, 0.97 RATIOResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2024 to June 30, 2024, 62 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2024 to June 30, 2024, 81 ppbResolved
Jan. 1, 2024 to March 31, 2024, 83 ppbResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2023 to Sept. 30, 2023, 66 ppbResolved
Total organic carbonNot enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor RemovalOct. 1, 2016 to Dec. 31, 2016Resolved
July 1, 2016 to Sept. 30, 2016Resolved
April 1, 2016 to June 30, 2016Resolved

Health-based violations only. 2 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total) results here are Maryland’s own from 2020 on, with EPA’s national file for 2012 to 2019. Town of North East’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 15, 2023 to Jan. 18, 2024; Maryland’s results run from Jan. 13, 2020 to July 8, 2026.

Testing your own tap

Town of North East’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Maryland certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Town of North East’s latest lead sampling in EPA’s records, 2021 to 2023, had a 90th percentile of 1.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Town of North East’s results flag: haloacetic acids (HAA5) and total trihalomethanes (TTHM). These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs Maryland certifies closest to the area Town of North East serves, or a kit by mail

The 3 labs Maryland certifies closest to the area Town of North East serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Batta Laboratories, LLC

    Newark, DE · about 13 miles

    Certified for asbestos

    (302) 737-3376

  • Community Environmental Laboratories, Inc.

    Aberdeen, MD · about 16 miles

    Certified for bacteria, nitrate, lead and copper

    (410) 273-7600

  • Brandywine Science Center

    Kennett Square, PA · about 22 miles

    Certified for bacteria, nitrate, lead and copper

    (610) 444-9850

All 92 certified labs for Maryland⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Maryland certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Maryland’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID MD0070016. Rebuilt from EPA data on Oct. 25, 2026.