Skip to content
TapBuff

City of Canton

EPA’s and Kansas’s records have results for 37 contaminants in its water; 7 were found.

Serves 699 people · Groundwater · Canton, KS · Hardness: very hard

Serves
699 people
Connections
333
Water source
Groundwater
Based in
Canton, KS
County
McPherson
Owner
Local government
Hardness
Very hard
The ZIP code it serves

67428

The short answer

EPA recorded a violation of the legal limit for arsenic here in 2020. In 2026, the latest year on file, it averaged 6.7 ppb, below the limit. Nitrate is above the health goal. Lithium is above EPA’s health benchmark. 10 health-based violations since 2016, all resolved in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 10 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from April 15, 2025 to Jan. 5, 2026.

Arsenic, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride and chromium (total): Kansas’s own results, samples taken from Jan. 14, 2020 to July 7, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

A legal-limit violation on record, below the limit in the latest year, 1 result

Arsenic

Comes from the source

Violation on record (2020)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.

9.3 ppb

Highest yearly average, 2020 to 2026

2026 average: 6.7 ppb

Averaged by year, the highest was 9.3 ppb, in 2020, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 12 ppb. In 2026, the latest year on file, its three samples averaged below the limit. EPA recorded a violation for arsenic at this utility in 2020.

How it’s judged

EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 25 ppb, in 2017, and EPA recorded violations in 2018 and 2019.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Above the health goal, 1 result

Nitrate

Comes from the source

Above the health goal

11 ppm

Highest sample; found in 14 of 14

2026 average: 8.9 ppm

In 2025, two samples were above EPA’s legal limit of 10 ppm, the highest 11 ppm. One came back under the limit on the next sample at the same point and one has no follow-up sample on file within 30 days. 10 ppm is also EPA’s health goal. In 2026, the latest year on file, its four samples averaged below the limit. EPA recorded no violation for nitrate at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 24 ppm, in 2018, and EPA recorded a violation in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

43.3 ppb

Highest sample, April 15, 2025; found in 2 of 2

The highest sample was 43.3 ppb, about 4.3 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 4 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 38 ppb

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 38 ppb, in 2025, below EPA’s legal limit of 80 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 55 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 8.4 ppb

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 8.4 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 18 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.28 ppm

Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment

Averaged by year, the highest was 0.28 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, it wasn’t found in any of its two samples.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.31 ppm, in 2017.

What handles it

About fluoride
Chromium (total), Legal limit 100 ppb; highest yearly average 3.5 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 1.4 ppb · Comes from the source

Averaged by year, the highest was 3.5 ppb, in 2020, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 3.4 ppb, in 2017.

What handles it

About chromium (total)
Kansas utilities above EPA’s PFAS limits⁠
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Nitrate/Nitrite (30 ppm challenge)

    For: Arsenic, Nitrate

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Nitrate/Nitrite Reduction

    For: Arsenic, Nitrate

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level); Nitrate

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best reverse osmosis systems, ranked⁠

Hardness

Very hard, typically 710 mg/L (41.5 grains per gallon), across 2 sampling points, 2017 to 2026.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

City of Canton reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 to 2026 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

10 health-based violations since 2016, 7 for arsenic and 3 for nitrate. The latest began July 1, 2020.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 2020, 11 ppbResolved
April 1, 2020 to June 30, 2020, 13 ppbResolved
Jan. 1, 2020 to March 31, 2020, 15 ppbResolved
Oct. 1, 2019 to Dec. 31, 2019, 14 ppbResolved
July 1, 2019 to Sept. 30, 2019, 16 ppbResolved
The other 5, back to 2018
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 2019, 14 ppbResolved
Oct. 1, 2018 to Dec. 31, 2018, 11 ppbResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2018 to Sept. 30, 2018, 14 ppmResolved
April 1, 2018 to June 30, 2018, 21 ppmResolved
Jan. 1, 2018 to Dec. 31, 2018, 24 ppmResolved

Health-based violations only. 16 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride and chromium (total) results here are Kansas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Canton’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from April 15, 2025 to Jan. 5, 2026; Kansas’s results run from Jan. 14, 2020 to July 7, 2026.

Testing your own tap

City of Canton’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Kansas certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of Canton’s latest lead sampling in EPA’s records, 2024, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What City of Canton’s results flag: arsenic, nitrate and lithium. These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs Kansas certifies closest to the area City of Canton serves, or a kit by mail

The 3 labs Kansas certifies closest to the area City of Canton serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, Inc. - Salina

    Salina, KS · about 34 miles

    Certified for bacteria, nitrate

    (913) 599-5665

  • Meridian Analytical Laboratory - Wichita

    Wichita, KS · about 52 miles

    Certified for bacteria, nitrate, minerals and other inorganics, organic chemicals, disinfection byproducts

    (316) 618-8787

  • Irwin Army Community Hospital-Water Laboratory-PH-EH

    Fort Riley, KS · about 60 miles

    Certified for bacteria

    (785) 239-7516

All 47 certified labs for Kansas⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Kansas certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Kansas’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID KS2011313. Rebuilt from EPA data on Oct. 25, 2026.