City of Caney
What EPA’s and Kansas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 1,756 people
- Connections
- 1,131
- Water source
- Surface water
- Based in
- Caney, KS
- County
- Montgomery
- Owner
- Local government
- Hardness
- Hard
The ZIP code it serves
The short answer
1 result is above EPA’s legal limit, and 2 more are above the health goal. The worst: Total trihalomethanes (TTHM), above the legal limit. 13 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 1996 to 2025.
Total trihalomethanes (TTHM), arsenic, haloacetic acids (HAA5), nitrate, fluoride and chromium (total): Kansas’s own results, samples taken from Feb. 3, 2020 to June 24, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Total trihalomethanes (TTHM)
Forms or is added in treatment
110ppb
Highest yearly average, 2020 to 2026
2026 average: 50 ppb
Averaged by year, the highest was 110 ppb, in 2023, above EPA’s legal limit of 80 ppb. Its highest single sample was 170 ppb. In 2026, the latest year on file, its two samples averaged 50 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2020, 2021, 2023 and 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 113 ppb, in 2014, and EPA recorded violations in 2014 and 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Above the health goal2
Lead
Comes from pipes, often your own
2.4ppb
90th percentile, 2023 to 2025
In the latest period, 9 in 10 homes sampled were at or below 2.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic
Comes from the source
1.4ppb
Highest yearly average, 2020 to 2026
2026: not found
Averaged by year, the highest was 1.4 ppb, in 2023: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.9 ppb, in 2013.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits4
Haloacetic acids (HAA5)
Forms or is added in treatment
20.1ppb
Highest yearly average, 2020 to 2026
2026 average: 5.5 ppb
Averaged by year, the highest was 20.1 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 47 ppb. In 2026, the latest year on file, its two samples averaged 5.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 41.8 ppb, in 2014.
What handles it
No certification claim covers this compound yet.
Nitrate
Comes from the source
0.88ppm
Highest sample; found in 3 of 13
2026: not found
The highest sample, in 2024, was 0.88 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.65 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
0.15ppm
Highest yearly average, 2020 to 2026
2026: not found
Averaged by year, the highest was 0.15 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.16 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total)
Comes from the source
1.4ppb
Highest yearly average, 2020 to 2026
2026: not found
Averaged by year, the highest was 1.4 ppb, in 2023, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.8 ppb, in 2013.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Total trihalomethanes (TTHM), Lead, Arsenic
Other certifiers’ wording: VOC Reduction; Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Total trihalomethanes (TTHM), Lead, Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Lead, Arsenic
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Total trihalomethanes (TTHM), Lead, Arsenic
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Lead
Brita Hub Countertop Water Filter System (87340)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Lead
Hardness
Hard, 130 mg/L (7.6 grains per gallon), at its one sampling point, 2015 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2024 to March 31, 2024 | 0.091 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2023 to Dec. 31, 2023 | 0.11 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2023 to Sept. 30, 2023 | 0.12 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2023 to June 30, 2023 | 0.11 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2023 to March 31, 2023 | 0.085 MG/L | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | April 1, 2021 to June 30, 2021 | 0.4 RATIO | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2021 to June 30, 2021 | 0.085 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021 | 0.09 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020 | 0.093 MG/L | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | Oct. 1, 2020 to Dec. 31, 2020 | — | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020 | 0.097 MG/L | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | July 1, 2020 to Sept. 30, 2020 | — | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | Jan. 1, 2017 to March 31, 2017 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 36 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), arsenic, haloacetic acids (HAA5), nitrate, fluoride and chromium (total) results here are Kansas’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Caney’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Kansas’s results run from Feb. 3, 2020 to June 24, 2026.
Testing your own tap
The lab Kansas certifies closest to the area City of Caney serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pace Analytical Services, Inc - Frontenac
Frontenac, KS · about 71 miles
Certified for bacteria
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Kansas Department of Health and Environment, Public Water Supply Section, results from Jan. 2, 2020 to Sept. 16, 2026, read Oct. 18, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Kansas Department of Health and Environment, drinking water labs, as listed in TNI LAMS, read Oct. 13, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Kansas Department of Health and Environment, Public Water Supply Section, results from April 13, 2015 to April 27, 2026, read Oct. 18, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID KS2012517. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 3 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Total trihalomethanes (TTHM)
- Get the utility’s own reportCity of Caney must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs