What EPA’s and Iowa’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
145 people
Connections
83
Water source
Groundwater
Based in
Bristow, IA
County
Butler
Owner
Local government
The ZIP code it serves

50611

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Nitrate, above the legal limit. 8 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2011 to 2023.

Nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, arsenic and chromium (total): Iowa’s own results, samples taken from Jan. 21, 2020 to Sept. 16, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Nitrate

Comes from the source

Above the legal limit

16.9ppm

Highest sample; found in 81 of 81

2026 average: 8.7 ppm

From 2024 to 2026, four samples were above EPA’s legal limit of 10 ppm, the highest 16.9 ppm in 2025. The next sample at the same point, within 30 days, kept the average above the limit for one; one came back under and two have no follow-up sample on file within 30 days. In 2026, the latest year on file, its nine samples averaged 8.7 ppm. EPA recorded violations for nitrate at this utility in 2024, 2025 and 2026. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 15.1 ppm, in 2018, and EPA recorded violations in 2014, 2016, 2017 and 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

1.2ppb

90th percentile, 2021 to 2023

In the latest period, 9 in 10 homes sampled were at or below 1.2 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

11.7ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 11.7 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 13.8 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

12.9ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 12.9 ppb, in 2025, below EPA’s legal limit of 80 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 14.3 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.1ppm

Highest yearly average, 2021

Averaged by year, the highest was 0.1 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.2 ppm, in 2012.

What handles it

2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Lead Reduction

    For: Nitrate, Lead

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Lead Reduction

    For: Nitrate, Lead

    Other certifiers’ wording: Nitrate

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2026 to April 30, 202612.4 MG/LArchived
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleAug. 1, 2025 to Aug. 31, 202511.8 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2025 to July 31, 202516.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2024 to July 31, 202411.1 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2018 to Oct. 31, 201810.6 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleSept. 1, 2018 to Sept. 30, 201815.1 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleMay 1, 2017 to May 31, 201711.1 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2016 to Oct. 31, 201612 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record.

What this report can’t tell you

  • Everything else. Nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, arsenic and chromium (total) results here are Iowa’s own from 2020 on, with EPA’s national file for 2012 to 2019. Bristow Muni Water Supply’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Iowa’s results run from Jan. 21, 2020 to Sept. 16, 2026.

Testing your own tap

Bristow Muni Water Supply’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Iowa certifies.

The 3 labs Iowa certifies closest to the area Bristow Muni Water Supply serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins - Cedar Falls

    Cedar Falls, IA · about 29 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (319) 277-2401

  • Microbac Laboratories - Waterloo

    Waterloo, IA · about 40 miles

    Certified for bacteria, nitrate

    (319) 235-4440

  • AgSource

    Ellsworth, IA · about 47 miles

    Certified for bacteria, nitrate, metals, minerals and other inorganics

    (515) 297-8103

State Hygienic Laboratory at the University of Iowa: Through the Grants-to-Counties program, private well owners in participating counties can have their water tested for total coliform bacteria and nitrate. Start with the county sanitarian at your county health department. No cost in a participating county. The Grants-to-Counties Program, State Hygienic Lab at the University of Iowa.

All 36 certified labs for Iowa

Sources