Ramsey Water Company, Inc. water quality report, rewritten
- Serves
- 16,475
- Connections
- 6,590
- Water source
- Groundwater
- Based in
- Ramsey, IN
- County
- Harrison
- Owner
- Local government
The 11 ZIP codes it serves
47112, 47114, 47115, 47119, 47122, 47124, 47136, 47137, 47161, 47164, 47166
PWSID IN52310052026 edition · EPA data
Read this first
- PFOA (above the health goal) was found in two of 2 samples, highest 5.2 ppt. Above the 4.0 ppt legal limit in at least one sample. Compliance is judged on a running annual average, not one sample.
1 health-based violation since 2016. Details are below.
What handles itWhat was found
Highlighted: above the health goal, or EPA’s health benchmark where there is no goal. Circled: above the legal limit in at least one sample, or the action level. Every scale puts that line at its middle.
PFOA (above the health goal)
Comes from the source
5.2 (above the legal limit in at least one sample)ppt
Highest of 2 samples; found in two
Above the 4.0 ppt legal limit in at least one sample. Compliance is judged on a running annual average, not one sample.
What handles it
- NSF/ANSI 53Look for: PFOA ReductionSame claim, other certifiers’ wording: Total PFAS Reduction; Perfluorooctanoic Acid (PFOA)
- NSF/ANSI 58Look for: Perfluorooctanoic Acid (PFOA)
NSF’s PFAS claims are tested to below 20 ppt. EPA’s limit is 4.0 ppt, and EPA says no certification yet shows a filter reaching its levels.
EPA UCMR 5, samples taken from March 26, 2024 to Sept. 11, 2024. Each blue tick is one sample where it was found.
Tested and not found
Below EPA’s minimum reporting level in every sample taken from March 26, 2024 to Sept. 11, 2024. Not found means not measured above that level, which is not the same as zero.
All 30 compounds tested and not found
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lead
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Groundwater Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | Feb. 1, 2026 to Feb. 28, 2026 | — | Archived |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: PFOA Reduction
For: PFOA
- NSF/ANSI 58
Claim: Perfluorooctanoic Acid (PFOA)
For: PFOA
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
ZeroWater 10 Cup Pitcher (ZP-010)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: PFOA
Aquasana Claryum Direct Connect (AQ-MF-1)
Under-sink carbon
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: PFOA
Under-sink reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58checked Oct. 4, 2026
Certified for: PFOA
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: PFOA
What this report cannot tell you
- Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in Ramsey Water Company, Inc.’s own annual report, which it must send you every year.
- Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
- Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from March 26, 2024 to Sept. 11, 2024.
What to do next
Read up on PFOA
What each one does to health, where it comes from, and the certification claim that addresses it.
About PFOAGet the utility’s own report
Ramsey Water Company, Inc. must send you a water quality report every year. It lists nitrate, arsenic and byproduct levels this page cannot.
How to read itTest your own tap for lead
Your service line, solder and fixtures decide the lead at your faucet, not the utility’s average.
Lead in your water: what to doCompare certified filters
What the filters certified for these results cost over five years, cartridges included.
Compare five-year costs
Other Indiana utilities
- Citizens Water - Indianapolis880,345
- Fort Wayne - 3 Rivers Filtration Plant269,994
- Indiana American Water - Northwest210,510
- Evansville Water Utility182,444
- South Bend Water Works115,000
- Indiana American Water - S. Indiana104,445
- Carmel Water Department99,927
- Indiana American Water - Johnson County86,813
- City of Bloomington Utilities83,000
- Hammond Water Works Department78,384
- Indiana American Water - Muncie74,030
- Lafayette Water Works70,835
Sources
- EPA UCMR 5 occurrence data, file of Aug. 27, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q2
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.