North Vernon Water Department
EPA’s and Indiana’s records have results for 37 contaminants in its water; 6 were found.
Serves 6,500 people · Surface water · North Vernon, IN
- Serves
- 6,500 people
- Connections
- 2,600
- Water source
- Surface water
- Based in
- North Vernon, IN
- County
- Jennings
- Owner
- Local government
The short answer
EPA recorded a violation of the legal limit for haloacetic acids (HAA5) here in 2020. In 2026, the latest year on file, it averaged 34.4 ppb, below the limit. EPA recorded violations of the legal limit for total trihalomethanes (TTHM) here in 2020 and 2021. In 2026, the latest year on file, it averaged 57.3 ppb, below the limit. 24 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What handles itThe 24 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 8 to Dec. 4, 2023.
Lead and copper: EPA SDWIS monitoring periods ending 2013 to 2025.
Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total): Indiana’s own results, samples taken from Feb. 10, 2020 to Aug. 3, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
A legal-limit violation on record, below the limit in the latest year, 2 results
Haloacetic acids (HAA5)
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.
63 ppb
Highest yearly average, 2020 to 2026
2026 average: 34.4 ppb
Averaged by year, the highest was 63 ppb, in 2020, above EPA’s legal limit of 60 ppb. Its highest single sample was 102 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 99.9 ppb, in 2015, and EPA recorded violations in 2014, 2015, 2016, 2017, 2018 and 2019.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM)
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.
79.8 ppb
Highest yearly average, 2020 to 2026
2026 average: 57.3 ppb
Averaged by year, the highest was 79.8 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 115 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2020 and 2021.
How it’s judged
EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 89.7 ppb, in 2015, and EPA recorded violations in 2015 and 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Below EPA’s limits, 4 results
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
Lithium, Health reference level 10 ppbAt EPA’s benchmark, as EPA rounds; highest 14.5 ppb
Highest sample, June 26, 2023; found in 4 of 4 · Comes from the source
The highest sample was 14.5 ppb. As EPA rounds results, that is at EPA’s health reference level of 10 ppb, not above it: EPA counts a result as above it from 15 ppb.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportLead, Action level 15 ppb · health goal zero; 90th percentile 1.9 ppb
90th percentile, 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.9 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate, Legal limit 10 ppm; highest 1.3 ppm
Highest sample; found in 12 of 15 · 2026, one sample: 0.37 ppm · Comes from the source
The highest sample, in 2020, was 1.3 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 3.5 ppm, in 2013.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.34 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.2 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.34 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.42 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction
For: Total trihalomethanes (TTHM), Lead
Other claims that cover it: VOC Reduction
- NSF/ANSI 58
Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction
For: Total trihalomethanes (TTHM), Lead
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
A.O. Smith 2-Stage Under Sink Water Filter (AO-US-200)
Under-sink carbon
Five years: $980, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
Aquasana Claryum 2-Stage (AQ-6200)
Under-sink carbon
Five years: $990, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
2 more filters
Brita Elite Water Filter Faucet System (SAFF-100/FF-100)
Faucet mount
Five years: $1,004, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
Five years: $1,061, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
Every filter certified for it
Disinfectant
North Vernon Water Department reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
24 health-based violations since 2016, 14 for total Haloacetic Acids (HAA5), 5 for the Groundwater Rule and 5 for TTHM. The latest began Jan. 21, 2022.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | Jan. 21, 2022 | Resolved |
| Jan. 21, 2022 | Resolved | ||
| Jan. 21, 2022 | Resolved | ||
| Jan. 21, 2022 | Resolved | ||
| Jan. 21, 2022 | Resolved |
The other 19, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021, 83.9 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020, 64.6 ppb | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020, 82.6 ppb | Resolved |
| July 1, 2020 to Sept. 30, 2020, 83.2 ppb | Resolved | ||
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020, 75 ppb | Resolved |
| April 1, 2020 to June 30, 2020, 79.5 ppb | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2020 to June 30, 2020, 84.7 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2020 to March 31, 2020, 72 ppb | Resolved |
| Oct. 1, 2019 to Dec. 31, 2019, 65.3 ppb | Resolved | ||
| July 1, 2019 to Sept. 30, 2019, 62.4 ppb | Resolved | ||
| Jan. 1, 2018 to March 31, 2018, 64.5 ppb | Resolved | ||
| Oct. 1, 2017 to Dec. 31, 2017, 68.8 ppb | Resolved | ||
| July 1, 2017 to Sept. 30, 2017, 73.7 ppb | Resolved | ||
| April 1, 2017 to June 30, 2017, 76.1 ppb | Resolved | ||
| Jan. 1, 2017 to March 31, 2017, 66.7 ppb | Resolved | ||
| July 1, 2016 to Sept. 30, 2016, 81.9 ppb | Resolved | ||
| April 1, 2016 to June 30, 2016, 86.8 ppb | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2016 to March 31, 2016, 80.4 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2016 to March 31, 2016, 89.9 ppb | Resolved |
Health-based violations only. 42 monitoring or reporting violations not shown.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total) results here are Indiana’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Vernon Water Department’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 8 to Dec. 4, 2023; Indiana’s results run from Feb. 10, 2020 to Aug. 3, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. North Vernon Water Department’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 1.9 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What North Vernon Water Department’s results flag: haloacetic acids (HAA5) and total trihalomethanes (TTHM). These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs Indiana certifies closest to the area North Vernon Water Department serves, or a kit by mail
The 3 labs Indiana certifies closest to the area North Vernon Water Department serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Environmental Laboratories, Inc. - Madison
Madison, IN · about 19 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
(812) 273-6699Website: Environmental Laboratories, Inc. - Madison
Element Laboratories -Columbus
Columbus, IN · about 23 miles
Certified for bacteria
Astbury Water Technology, Inc.-Clarksville
Clarksville, IN · about 48 miles
Certified for bacteria
(812) 282-8481Website: Astbury Water Technology, Inc.-Clarksville
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Indiana certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Indiana’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on these 2 resultsWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with haloacetic acids (HAA5)
- Get the utility’s own reportNorth Vernon Water Department must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Indiana Department of Environmental Management, Drinking Water Viewer, results from Jan. 1, 2020 to Oct. 20, 2026, read Oct. 24, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Indiana Department of Health, certified drinking water laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID IN5240008. Rebuilt from EPA data on Oct. 25, 2026.