What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,178 people
Connections
471
Water source
Groundwater
Based in
Russiaville, IN
County
Howard
Owner
Local government
The ZIP code it serves

46979

The short answer

3 results are above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1995 to 2023.

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.5 ppm, for the period ending Dec. 31, 2019. None since is on file, so it is not counted as a current finding.

Uranium, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Indiana’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2022 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Arsenic, fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Aug. 2, 2012 to July 9, 2018. Newer results are in the utility’s annual water quality report.

Above the health goal3

Lead

Comes from pipes, often your own

Above the health goal

2.0ppb

90th percentile, 2023

In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

0.7ppb

Highest yearly average, 2012 to 2018

2018: not found

Averaged by year, the highest was 0.7 ppb, in 2012: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2018, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

0.02ppb

Highest yearly average, 2023

Averaged by year, the highest was 0.02 ppb, in 2023: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

53.2ppb

Highest yearly average, 2022 to 2023

2023 average: 38.1 ppb

Averaged by year, the highest was 53.2 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2023, the latest year on file, it averaged 38.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 62.1 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

28.4ppb

Highest yearly average, 2022 to 2023

2023 average: 22 ppb

Averaged by year, the highest was 28.4 ppb, in 2022, below EPA’s legal limit of 60 ppb. In 2023, the latest year on file, it averaged 22 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 54.8 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.99ppm

Highest yearly average, 2012 to 2018

2018, one sample: 0.95 ppm

Averaged by year, the highest was 0.99 ppm, in 2012, below EPA’s legal limit of 4.0 ppm. In 2018, the latest year on file, its one sample was 0.95 ppm.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.02ppm

Highest yearly average, 2022 to 2023

2023 average: 0.01 ppm

Averaged by year, the highest was 0.02 ppm, in 2022, below EPA’s legal limit of 10 ppm. In 2023, the latest year on file, it averaged 0.01 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 1.2 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium

    For: Lead, Arsenic, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016.

What this report can’t tell you

  • Everything else. Uranium, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Indiana’s yearly averages as CDC publishes them, from 2022 on, with EPA’s national file for 2012 to 2019. Arsenic, fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Indiana American Water - Russiaville’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Indiana cover 2022 to 2023; EPA’s compliance samples are from Aug. 2, 2012 to July 9, 2018.

Testing your own tap

Indiana American Water - Russiaville’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Indiana certifies.

The 3 labs Indiana certifies closest to the area Indiana American Water - Russiaville serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

Indiana Department of Health laboratory: Test kits for well water: nitrate, fluoride, and arsenic, lead and copper, ordered from the lab and returned by mail. They are open to the public. Nitrate is $10 a sample plus $6.50 shipping per order, fluoride $10 plus shipping, and the arsenic, lead and copper kit $20 plus $6.50 shipping. Water Testing, Indiana Department of Health.

All 81 certified labs for Indiana

Sources

PWSID IN5234008. Rebuilt from EPA data on Oct. 18, 2026.