Skip to content
TapBuff

Indiana American Water - Georgetown

EPA’s and Indiana’s records have results for 33 contaminants in its water; 2 were found.

Serves 3,605 people · Groundwater bought from another system · Georgetown, IN

Serves
3,605 people
Connections
1,442
Water source
Groundwater bought from another system
Based in
Georgetown, IN
County
Floyd
Owner
Local government
The ZIP code it serves

47122

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from June 6 to Dec. 6, 2023.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Indiana’s own results, samples taken from Sept. 14, 2020 to Sept. 2, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 44.6 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 44.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 44.6 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 46.5 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 58 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 23.9 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 21.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 23.9 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 24.1 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 26.3 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Indiana utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Indiana American Water - Georgetown reported adding no disinfectant at its one sampling point, in its 2023 sampling for EPA.

What that means

Most utilities add chlorine or chloramine, CDC says. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Indiana’s own from 2020 on, with EPA’s national file for 2012 to 2019. Indiana American Water - Georgetown’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 6 to Dec. 6, 2023; Indiana’s results run from Sept. 14, 2020 to Sept. 2, 2026.

Testing your own tap

Indiana American Water - Georgetown’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Indiana certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Indiana American Water - Georgetown’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Indiana certifies closest to the area Indiana American Water - Georgetown serves, or a kit by mail

The 3 labs Indiana certifies closest to the area Indiana American Water - Georgetown serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Astbury Water Technology, Inc.-Clarksville

    Clarksville, IN · about 12 miles

    Certified for bacteria

    (812) 282-8481Website: Astbury Water Technology, Inc.-Clarksville

  • Microbac Laboratories, Inc.-KTL

    Louisville, KY · about 17 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (502) 962-6400

  • Beckmar Environmental Laboratory

    Louisville, KY · about 28 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (502) 266-6533

All 81 certified labs for Indiana⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Indiana certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Indiana’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID IN5222003. Rebuilt from EPA data on Oct. 25, 2026.