Quincy, City of W/S
EPA’s and Florida’s records have results for 37 contaminants in its water; 7 were found.
Serves 10,298 people · Surface water · Quincy, FL
- Serves
- 10,298 people
- Connections
- 4,119
- Water source
- Surface water
- Based in
- Quincy, FL
- County
- Gadsden
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 4 health-based violations since 2016, 1 with no fix on record in EPA’s file.
Filters for lead and arsenic, if you want them lowerThe 4 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from July 18, 2023 to Jan. 10, 2024.
Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2023.
Haloacetic acids (HAA5), arsenic, nitrate, fluoride, chromium (total) and total trihalomethanes (TTHM): Florida’s own results, samples taken from Aug. 18, 2020 to Aug. 21, 2024, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 7 results
Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 11 ppb
Highest yearly average, 2020 to 2024 · 2024 average: 0.65 ppb · Forms or is added in treatment
Averaged by year, the highest was 11 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 12.3 ppb. In 2024, the latest year on file, its two samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 16.9 ppb, in 2017.
What handles it
No certification claim covers this compound yet.
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.3 ppb
90th percentile, 2023 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.3 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.8 ppb
Highest yearly average, 2020 to 2021 · Comes from the source
Averaged by year, the highest was 0.8 ppb, in 2021, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Nitrate, Legal limit 10 ppm; highest 0.64 ppm
Highest sample; found in 17 of 25 · 2024 average: 0.42 ppm · Comes from the source
The highest sample, in 2024, was 0.64 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.6 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.25 ppm
Highest yearly average, 2020 to 2021 · 2021 average: 0.078 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.25 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.57 ppm. In 2021, the latest year on file, its two samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.21 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total), Legal limit 100 ppb; highest yearly average 3.0 ppb
Highest yearly average, 2020 to 2021 · Comes from the source
Averaged by year, the highest was 3.0 ppb, in 2021, below EPA’s legal limit of 100 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 3.9 ppb, in 2017.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 2.3 ppb
Highest yearly average, 2020 to 2024 · Forms or is added in treatment
Averaged by year, the highest was 2.3 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 3.1 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 8.7 ppb, in 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
4 health-based violations since 2016, all for pentachlorophenol. The latest began Jan. 1, 2021, and 1 has no fix on record in EPA’s file.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Pentachlorophenol | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021, 2.2 UG/L | Resolved |
| Oct. 1, 2020 to Dec. 31, 2020, 2.9 UG/L | Resolved | ||
| July 1, 2020 to Sept. 30, 2020, 8.6 UG/L | No fix on recordEPA: archived | ||
| April 1, 2020 to June 30, 2020, 8.6 UG/L | Resolved |
Health-based violations only. 1 monitoring or reporting violation not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Disinfectant
Quincy, City of W/S reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 to 2024 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), arsenic, nitrate, fluoride, chromium (total) and total trihalomethanes (TTHM) results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Quincy, City of W/S’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from July 18, 2023 to Jan. 10, 2024; Florida’s results run from Aug. 18, 2020 to Aug. 21, 2024.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Quincy, City of W/S’s latest lead sampling in EPA’s records, 2023, had a 90th percentile of 1.3 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Florida certifies closest to the area Quincy, City of W/S serves, or a kit by mail
The 3 labs Florida certifies closest to the area Quincy, City of W/S serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Ackuritlabs, Inc.
Tallahassee, FL · about 18 miles
Certified for bacteria
Advanced Environmental Laboratories, Inc. - Tallahassee
Tallahassee, FL · about 18 miles
Certified for bacteria, minerals and other inorganics
Talquin Electric Cooperative, Inc.
Tallahassee, FL · about 18 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Florida certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Florida’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Florida’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportQuincy, City of W/S must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Florida Department of Environmental Protection, Drinking Water Program, results from Jan. 2, 2020 to Dec. 31, 2024, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Florida Department of Health Environmental Laboratory Certification Program, drinking water labs, as listed in TNI LAMS, read Oct. 11, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID FL1200551. Rebuilt from EPA data on Oct. 25, 2026.