Skip to content
TapBuff

Walden WSD

What EPA’s and Colorado’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,500 people
Connections
360
Water source
Groundwater
Based in
Monument, CO
County
El Paso
Owner
Local government
The ZIP code it serves

80908

The short answer

Nothing in EPA’s and Colorado’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.4 ppm, for the period ending Dec. 31, 2016. None since is on file, so it is not counted as a current finding.

Nitrate, fluoride, chromium (total), arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium: Colorado’s own results, samples taken from Sept. 25, 2020 to Aug. 25, 2026, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

2.4ppm

Highest sample; found in 12 of 12

2025 average: 1.2 ppm

The highest sample, in 2022, was 2.4 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its two samples averaged 1.2 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.3 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.47ppm

Highest yearly average, 2020 to 2023

2023, one sample: 0.47 ppm

Averaged by year, the highest was 0.47 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.49 ppm. In 2023, the latest year on file, its one sample was 0.47 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.48 ppm, in 2012.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

2.0ppb

Highest yearly average, 2020 to 2021

Averaged by year, the highest was 2.0 ppb, in 2021, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Haloacetic acids (HAA5)
  • Lead
  • Total trihalomethanes (TTHM)
  • Uranium

Violations since 2016

No health-based violations on file with EPA since 2016. There are 10 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Nitrate, fluoride, chromium (total), arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. Walden WSD’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Colorado’s results run from Sept. 25, 2020 to Aug. 25, 2026.

Testing your own tap

Walden WSD’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Colorado certifies.

The 3 labs Colorado certifies closest to the area Walden WSD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • El Paso County Health Department

    Colorado Springs, CO · about 14 miles

    Certified for bacteria, nitrate, minerals and other inorganics

  • Colorado Department of Health & Environment

    Denver, CO · about 48 miles

    Certified for bacteria

  • SGS North America, Inc. - Denver

    Denver, CO · about 52 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics

All 54 certified labs for Colorado

Sources

PWSID CO0121850. Rebuilt from EPA data on Oct. 18, 2026.