Skip to content
TapBuff

Greeley Rv Park

What EPA’s and Colorado’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
164 people
Connections
98
Water source
Groundwater
Based in
Los Altos, CO
County
Weld
Owner
Private

The short answer

3 results are above the health goal. The worst: Nitrate, above the health goal. 8 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2022 to 2028.

Nitrate, arsenic, fluoride, chromium (total), total trihalomethanes (TTHM), haloacetic acids (HAA5) and uranium: Colorado’s own results, samples taken from Jan. 27, 2020 to Oct. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal3

Nitrate

Comes from the source

Above the health goal

10.6ppm

Highest sample; found in 83 of 83

2026 average: 5.5 ppm

One sample, in 2023, was above EPA’s legal limit of 10 ppm, at 10.6 ppm. The next sample at the same point, within 30 days, brought the average back under the limit. 10 ppm is also EPA’s health goal. In 2026, the latest year on file, its 10 samples averaged 5.5 ppm. EPA recorded no violation for nitrate at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 12.8 ppm, in 2017, and EPA recorded violations in 2015, 2016 and 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Arsenic

Comes from the source

Above the health goal

2.0ppb

Highest yearly average, 2022 to 2023

2023 average: 2.0 ppb

Averaged by year, the highest was 2.0 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2023, the latest year on file, its two samples averaged 2.0 ppb.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Lead

Comes from pipes, often your own

Above the health goal

0.5ppb

90th percentile, 2026 to 2028

In the latest period, 9 in 10 homes sampled were at or below 0.5 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits4

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.63ppm

Highest yearly average, 2022 to 2023

2023 average: 0.56 ppm

Averaged by year, the highest was 0.63 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.68 ppm. In 2023, the latest year on file, its two samples averaged 0.56 ppm.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

4.5ppb

Highest yearly average, 2022 to 2023

Averaged by year, the highest was 4.5 ppb, in 2023, below EPA’s legal limit of 100 ppb. Its highest single sample was 5.0 ppb. That was also the latest year on file.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

3.2ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 3.2 ppb, in 2025, below EPA’s legal limit of 80 ppb. That was also the latest year on file.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.6ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 1.6 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Nitrate, Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Nitrate, Arsenic, Lead

    Other certifiers’ wording: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
NitrateThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 201712.8 MG/LResolved
NitrateThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 201712 MG/LResolved
NitrateThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201712 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2017 to March 31, 201712.6 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2016 to Dec. 31, 201612 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2016 to Sept. 30, 201612 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2016 to June 30, 201610.8 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2016 to March 31, 201611 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 5 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, arsenic, fluoride, chromium (total), total trihalomethanes (TTHM), haloacetic acids (HAA5) and uranium results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. Greeley Rv Park’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Colorado’s results run from Jan. 27, 2020 to Oct. 6, 2026.

Testing your own tap

Greeley Rv Park’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Colorado certifies.

No lab Colorado certifies is within 75 miles of the area Greeley Rv Park serves on the state’s list. Some take samples by mail; the state’s page lists them all.

All 54 certified labs for Colorado

Sources

PWSID CO0162302. Rebuilt from EPA data on Oct. 18, 2026.