City of Yuma
EPA’s and Colorado’s records have results for 38 contaminants in its water; 8 were found.
Serves 4,049 people · Groundwater · Yuma, CO
- Serves
- 4,049 people
- Connections
- 1,505
- Water source
- Groundwater
- Based in
- Yuma, CO
- County
- Yuma
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from June 11 to Dec. 2, 2024.
Arsenic, nitrate, total trihalomethanes (TTHM), uranium, fluoride, chromium (total) and haloacetic acids (HAA5): Colorado’s own results, samples taken from March 3, 2020 to Sept. 23, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
31.1 ppb
Highest sample, June 11, 2024; found in 12 of 12
The highest sample was 31.1 ppb, about 3.1 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 7 results
Arsenic and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 8.8 ppb
Highest yearly average, 2020 to 2025 · Comes from the source
Averaged by year, the highest was 8.8 ppb, in 2025, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 9.0 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 8.0 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Nitrate, Legal limit 10 ppm; highest 4.3 ppm
Highest sample; found in 42 of 42 · 2026 average: 2.6 ppm · Comes from the source
The highest sample, in 2025, was 4.3 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 6.4 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 18.9 ppb
Highest yearly average, 2020 to 2026 · 2026, one sample: 2.9 ppb · Forms or is added in treatment
Averaged by year, the highest was 18.9 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 3.2 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 7.0 ppb
Highest yearly average, 2025 · Comes from the source
Averaged by year, the highest was 7.0 ppb, in 2025, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 7.2 ppb. That is the only year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 7.8 ppb, in 2016.
What handles it
- NSF/ANSI 58 look for “Uranium”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.87 ppm
Highest yearly average, 2020 to 2025 · 2025 average: 0.85 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.87 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.9 ppm. In 2025, the latest year on file, its five samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.92 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total), Legal limit 100 ppb; highest yearly average 4.3 ppb
Highest yearly average, 2020 to 2025 · Comes from the source
Averaged by year, the highest was 4.3 ppb, in 2025, below EPA’s legal limit of 100 ppb. Its highest single sample was 5.0 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 2.3 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 1.8 ppb
Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment
Averaged by year, the highest was 1.8 ppb, in 2024, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
No certification claim covers this compound yet.
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 67 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium
For: Arsenic, Uranium
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Arsenic
One more filter
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Arsenic
Disinfectant
City of Yuma reported disinfecting with chlorine, not chloramine, at all 6 of its sampling points, in its 2024 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Arsenic, nitrate, total trihalomethanes (TTHM), uranium, fluoride, chromium (total) and haloacetic acids (HAA5) results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Yuma’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 11 to Dec. 2, 2024; Colorado’s results run from March 3, 2020 to Sept. 23, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of Yuma’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What City of Yuma’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 2 labs Colorado certifies closest to the area City of Yuma serves, or a kit by mail
The 2 labs Colorado certifies closest to the area City of Yuma serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Northeast Colorado Health Dept.
Sterling, CO · about 45 miles
Certified for bacteria
Fort Morgan, City of
Ft. Morgan, CO · about 63 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Colorado certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Colorado’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportCity of Yuma must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Colorado Department of Public Health and Environment, Water Quality Control Division, results from Jan. 3, 2020 to Oct. 6, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: CDPHE certified drinking water laboratories, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CO0163020. Rebuilt from EPA data on Oct. 25, 2026.