Bobcat Meadows MD
What EPA’s and Colorado’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 470 people
- Connections
- 170
- Water source
- Groundwater
- Based in
- Woodland Park, CO
- County
- El Paso
- Owner
- Private
The ZIP code it serves
The short answer
Nothing in EPA’s and Colorado’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), chromium (total), arsenic, nitrate and uranium: Colorado’s own results, samples taken from Feb. 14, 2020 to Jan. 13, 2026, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits4
Total trihalomethanes (TTHM)
Forms or is added in treatment
22.2ppb
Highest yearly average, 2021 to 2024
2024, one sample: 21.3 ppb
Averaged by year, the highest was 22.2 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2024, the latest year on file, its one sample was 21.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 26 ppb, in 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Fluoride
Forms or is added in treatment
1.0ppm
Highest yearly average, 2020
Averaged by year, the highest was 1.0 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.0 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Haloacetic acids (HAA5)
Forms or is added in treatment
2.1ppb
Highest yearly average, 2021 to 2024
Averaged by year, the highest was 2.1 ppb, in 2024, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.1 ppb, in 2013.
What handles it
No certification claim covers this compound yet.
Chromium (total)
Comes from the source
2.0ppb
Highest yearly average, 2020
Averaged by year, the highest was 2.0 ppb, in 2020, below EPA’s legal limit of 100 ppb. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Lead
- Nitrate
- Uranium
Violations since 2016
No health-based violations on file with EPA since 2016.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), chromium (total), arsenic, nitrate and uranium results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. Bobcat Meadows MD’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Colorado’s results run from Feb. 14, 2020 to Jan. 13, 2026.
Testing your own tap
The 3 labs Colorado certifies closest to the area Bobcat Meadows MD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
El Paso County Health Department
Colorado Springs, CO · about 20 miles
Certified for bacteria, nitrate, minerals and other inorganics
Pueblo Department of Public Health and Environment
Pueblo, CO · about 50 miles
Certified for bacteria
Colorado Department of Health & Environment
Denver, CO · about 54 miles
Certified for bacteria
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Colorado Department of Public Health and Environment, Water Quality Control Division, results from Jan. 3, 2020 to Oct. 6, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: CDPHE certified drinking water laboratories, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CO0121060. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and Colorado’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportBobcat Meadows MD must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded