Yolo Co Housing Authority - El Rio Villa
What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 432 people
- Connections
- 13
- Water source
- Groundwater
- Based in
- Woodland, CA
- County
- Yolo
- Owner
- Local government
- Hardness
- Varies by source
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Arsenic, nitrate, chromium (total), total trihalomethanes (TTHM), fluoride and haloacetic acids (HAA5): California’s own results, samples taken from Jan. 23, 2020 to July 6, 2026, with EPA’s 2012 to 2019 file for earlier years.
Uranium: EPA’s compliance monitoring file, samples taken from July 5, 2017 to Feb. 20, 2019. Newer results are in the utility’s annual water quality report.
Above the health goal2
Arsenic
Comes from the source
2.3ppb
Highest yearly average, 2020 to 2026
2026: not found
Averaged by year, the highest was 2.3 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.9 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Uranium
Comes from the source
0.35ppb
Highest yearly average, 2017 to 2019
Averaged by year, the highest was 0.35 ppb, in 2019: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Uranium”
Below EPA’s limits5
Nitrate
Comes from the source
7.3ppm
Highest sample; found in 13 of 13
2026, one sample: 7.3 ppm
The highest sample, in 2026, was 7.3 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was 7.3 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 7.9 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total)
Comes from the source
26ppb
Highest yearly average, 2020 to 2026
2026, one sample: 14 ppb
Averaged by year, the highest was 26 ppb, in 2025, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, its one sample was 14 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 25 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Total trihalomethanes (TTHM)
Forms or is added in treatment
6.0ppb
Highest yearly average, 2020 to 2024
Averaged by year, the highest was 6.0 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 10 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Fluoride
Forms or is added in treatment
0.19ppm
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 0.19 ppm, in 2026, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.58 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Haloacetic acids (HAA5)
Forms or is added in treatment
1.4ppb
Highest yearly average, 2021 to 2024
2024 average: 0.7 ppb
Averaged by year, the highest was 1.4 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 1.6 ppb. In 2024, the latest year on file, its two samples averaged 0.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.4 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Lead
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium
For: Arsenic, Uranium
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Hardness
Moderately hard to very hard depending on the source, 90 to 270 mg/L (5.3 to 15.8 grains per gallon), across 3 sampling points, 2019 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Arsenic, nitrate, chromium (total), total trihalomethanes (TTHM), fluoride and haloacetic acids (HAA5) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Yolo Co Housing Authority - El Rio Villa’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 23, 2020 to July 6, 2026; EPA’s compliance samples are from July 5, 2017 to Feb. 20, 2019.
Testing your own tap
The 3 labs California certifies closest to the area Yolo Co Housing Authority - El Rio Villa serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Napa-Solano-Yolo-Marin Public Health Laboratory
Fairfield, CA · about 23 miles
Certified for bacteria
Caltest Analytical Laboratory
Napa, CA · about 26 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Eurofins Sacramento Service Center
West Sacramento, CA · about 27 miles
Certified for bacteria, nitrate, minerals and other inorganics
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from Feb. 20, 2019 to June 2, 2026, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA5700615. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Arsenic
- Get the utility’s own reportYolo Co Housing Authority - El Rio Villa must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs