Skip to content
TapBuff

Triple R Mutual Water Co

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
408 people
Connections
154
Water source
Groundwater
Based in
Springville, CA
County
Tulare
Owner
Private
Hardness
Very hard
The ZIP code it serves

93265

The short answer

1 result is above EPA’s legal limit, 1 more is above the limit’s level with no violation recorded, and 1 more is above the health goal. The worst: Nitrate, above the legal limit. 30 health-based violations since 2016.

What handles it

What was found

Nitrate, uranium, arsenic, fluoride, chromium (total), total trihalomethanes (TTHM) and haloacetic acids (HAA5): California’s own results, samples taken from March 22, 2020 to June 30, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Nitrate

Comes from the source

Above the legal limit

20.7ppm

Highest sample; found in 291 of 299

2026 average: 18.1 ppm

From 2020 to 2026, at least 25 samples were above EPA’s legal limit of 10 ppm, the highest 20.7 ppm in 2026. The next sample at the same point, within 30 days, kept the average above the limit for one; 24 have no follow-up sample on file within 30 days. That was also the latest year on file, and its 12 samples averaged 18.1 ppm, above the limit. EPA recorded violations for nitrate at this utility in 2020, 2021 and 2022. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 19 ppm, in 2012, and EPA recorded violations in 2013, 2014, 2017, 2018 and 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Above the limit’s level, no violation recorded1

Uranium

Comes from the source

Above the limit’s level, no violation

31.6ppb

Highest yearly average, 2020 to 2025

Averaged by year, the highest was 31.6 ppb, in 2025, above EPA’s legal limit of 30 ppb. That was also the latest year on file. EPA judges this limit on running averages at each sampling point, and recorded no violation for uranium at this utility since 2020. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 24.2 ppb, in 2019.

What handles it

Above the health goal1

Arsenic

Comes from the source

Above the health goal

9.3ppb

Highest yearly average, 2022 to 2025

2025, one sample: 7.0 ppb

Averaged by year, the highest was 9.3 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 28 ppb. In 2025, the latest year on file, its one sample was 7.0 ppb. EPA recorded no violation for arsenic at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 17 ppb, in 2017, and EPA recorded violations in 2016 and 2017.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits3

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.2ppm

Highest yearly average, 2022 to 2023

Averaged by year, the highest was 0.2 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.2 ppm, in 2012.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

3.3ppb

Highest yearly average, 2022 to 2023

2023: not found

Averaged by year, the highest was 3.3 ppb, in 2022, below EPA’s legal limit of 100 ppb. Its highest single sample was 20 ppb. In 2023, the latest year on file, it wasn’t found in its one sample.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

2.0ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 2.0 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.0 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Haloacetic acids (HAA5)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Uranium, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Uranium, Arsenic

    Other certifiers’ wording: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Hardness

Very hard, typically 394 mg/L (23 grains per gallon), across 10 sampling points, 2019 to 2023.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Unaddressed
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2022 to Dec. 31, 202214.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2022 to Sept. 30, 202216.2 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2022 to June 30, 202216.2 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2022 to March 31, 202214.4 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2021 to Dec. 31, 202113.6 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2021 to Sept. 30, 202116.4 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2021 to June 30, 202115.2 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2021 to March 31, 202113.4 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2020 to Dec. 31, 202014.7 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2020 to Sept. 30, 202014.5 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2020 to June 30, 202014.7 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2020 to March 31, 202013.7 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2019 to Dec. 31, 201914.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2019 to Sept. 30, 201914.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2019 to June 30, 201913.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2019 to March 31, 201914.2 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2018 to Dec. 31, 201813.9 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2018 to Sept. 30, 201815.5 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2018 to June 30, 201814.6 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2018 to March 31, 201812.7 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleOct. 1, 2017 to Dec. 31, 201712.8 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJuly 1, 2017 to Sept. 30, 201714.4 MG/LResolved
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2017 to June 30, 201713.5 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 20170.015 MG/LResolved
Revised Total Coliform RuleE. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR)Jan. 1, 2017 to Jan. 31, 2017—Resolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 20160.016 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 20160.015 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 20160.014 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 20160.019 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown.

What this report can’t tell you

  • Everything else. Nitrate, uranium, arsenic, fluoride, chromium (total), total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Triple R Mutual Water Co’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from March 22, 2020 to June 30, 2026.

Testing your own tap

Triple R Mutual Water Co’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Triple R Mutual Water Co serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Sierra Dairy Laboratory

    Tulare, CA · about 36 miles

    Certified for bacteria

    (559) 686-2070

  • Fruit Growers Laboratory, Inc.

    Visalia, CA · about 40 miles

    Certified for bacteria

    (559) 734-9473

  • Inyo County Water Lab

    Independence, CA · about 47 miles

    Certified for bacteria

    (760) 878-8476

All 145 certified labs for California

Sources

PWSID CA5400670. Rebuilt from EPA data on Oct. 18, 2026.