Skip to content
TapBuff

Laguna Seca WC

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
162 people
Connections
58
Water source
Groundwater
Based in
Salinas, CA
County
Monterey
Owner
Private
Hardness
Very hard
The ZIP code it serves

93908

The short answer

2 results are above EPA’s legal limit, and 1 more is above the health goal. The worst: Arsenic, above the legal limit. 27 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2020 to 2026.

Arsenic, chromium (total), nitrate and fluoride: California’s own results, samples taken from March 12, 2020 to June 11, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit2

Arsenic

Comes from the source

Above the legal limit

30.2ppb

Highest yearly average, 2020 to 2026

2026 average: 9.8 ppb

Averaged by year, the highest was 30.2 ppb, in 2023, about 3 times EPA’s legal limit of 10 ppb. Its highest single sample was 101 ppb. In 2026, the latest year on file, its eight samples averaged 9.8 ppb. EPA recorded violations for arsenic at this utility in 2020, 2021, 2022, 2023 and 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 13.8 ppb, in 2017, and EPA recorded violations in 2012, 2013, 2014, 2015, 2016, 2017 and 2019.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Copper

Comes from pipes, often your own

Above the action level

2.3ppm

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 2.3 ppm, above EPA’s action level of 1.3 ppm.

What handles it

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

4.6ppb

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 4.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Chromium (total)

Comes from the source

Below EPA’s limits

28.1ppb

Highest yearly average, 2022 to 2026

2026: not found

Averaged by year, the highest was 28.1 ppb, in 2023, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 8.0 ppb, in 2014.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

2.4ppm

Highest sample; found in 12 of 13

2026 average: 2.3 ppm

The highest sample, in 2022, was 2.4 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its two samples averaged 2.3 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.5 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.2ppm

Highest yearly average, 2022 to 2026

2026 average: 0.05 ppm

Averaged by year, the highest was 0.2 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its two samples averaged 0.05 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.2 ppm, in 2014.

What handles it

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Copper Reduction, Lead Reduction

    For: Arsenic, Copper, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Copper Reduction, Lead Reduction

    For: Arsenic, Copper, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Hardness

Very hard, typically 389 mg/L (22.7 grains per gallon), across 2 sampling points, 2022 to 2026.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2024 to Dec. 31, 20240.013 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2024 to Sept. 30, 20240.013 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2024 to June 30, 20240.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2024 to March 31, 20240.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2023 to Dec. 31, 20230.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2023 to Sept. 30, 20230.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 20230.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 20230.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 20220.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 20220.013 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 20220.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 20220.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2021 to Dec. 31, 20210.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2021 to Dec. 31, 20210.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 20210.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 20210.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 20200.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 20200.011 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2020 to June 30, 20200.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 30, 20200.013 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Dec. 31, 20190.013 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 20190.012 MG/LArchived
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 20170.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 20160.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 20160.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 20160.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 20160.011 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record.

What this report can’t tell you

  • Everything else. Arsenic, chromium (total), nitrate and fluoride results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Laguna Seca WC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from March 12, 2020 to June 11, 2026.

Testing your own tap

Laguna Seca WC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Laguna Seca WC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Monterey County Consolidated Environmental Laboratory

    Salinas, CA · about 4 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (831) 755-4516

  • Monterey Bay Analytical Services, Inc.

    Monterey, CA · about 13 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, radioactivity

    (831) 375-6227

  • CM Analytical, Inc.

    Gilroy, CA · about 24 miles

    Certified for bacteria

    (408) 848-3619

All 145 certified labs for California

Sources