Skip to content
TapBuff

Jackson Hide - A - Way

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
25 people
Connections
26
Water source
Groundwater
Based in
Ocotillo, CA
County
Imperial
Owner
Private
Hardness
Moderately hard
The ZIP code it serves

92259

The short answer

Nothing in EPA’s and California’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Nitrate, fluoride, arsenic, chromium (total) and uranium: California’s own results, samples taken from March 14, 2022 to Oct. 6, 2025, with EPA’s 2012 to 2019 file for earlier years.

Total trihalomethanes (TTHM): EPA’s compliance monitoring file, samples taken from April 23, 2019 to April 23, 2019. Newer results are in the utility’s annual water quality report.

Below EPA’s limits2

Nitrate

Comes from the source

Below EPA’s limits

2.6ppm

Highest sample; found in 8 of 8

2025 average: 1.2 ppm

The highest sample, in 2023, was 2.6 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its five samples averaged 1.2 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 3.1 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.43ppm

Highest yearly average, 2022 to 2025

2025, one sample: 0.22 ppm

Averaged by year, the highest was 0.43 ppm, in 2023, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 0.22 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.34 ppm, in 2019.

What handles it

5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead
  • Total trihalomethanes (TTHM)
  • Uranium

Hardness

Moderately hard, 62 mg/L (3.6 grains per gallon), at its one sampling point, in 2023.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Nitrate, fluoride, arsenic, chromium (total) and uranium results here are California’s own from 2022 on, with EPA’s national file for 2012 to 2019. Total trihalomethanes (TTHM) comes from EPA’s file alone, which ends in 2019. Jackson Hide - A - Way’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from March 14, 2022 to Oct. 6, 2025; EPA’s compliance samples are from April 23, 2019 to April 23, 2019.

Testing your own tap

Jackson Hide - A - Way’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Jackson Hide - A - Way serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Babcock Laboratories, Inc.

    El Centro, CA · about 21 miles

    Certified for bacteria

    (951) 653-3351

  • Imperial County Public Health Laboratory

    El Centro, CA · about 22 miles

    Certified for bacteria

    (442) 265-1427

  • Brawley Analytical, Inc.

    Brawley, CA · about 29 miles

    Certified for bacteria, minerals and other inorganics

    (760) 623-1556

All 145 certified labs for California

Sources

PWSID CA1300629. Rebuilt from EPA data on Oct. 18, 2026.