Payson Water - Meads Ranch
What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 172 people
- Connections
- 74
- Water source
- Groundwater
- Based in
- Tonto Creek, AZ
- County
- Gila
- Owner
- Private
The ZIP code it serves
The short answer
1 result is above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Arsenic, nitrate, haloacetic acids (HAA5) and total trihalomethanes (TTHM): Arizona’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal1
Arsenic
Comes from the source
1.4ppb
Highest yearly average, 2020
Averaged by year, the highest was 1.4 ppb, in 2020: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits1
Nitrate
Comes from the source
0.07ppm
Highest yearly average, 2020 to 2023
Averaged by year, the highest was 0.07 ppm, in 2023, below EPA’s legal limit of 10 ppm. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Haloacetic acids (HAA5)
- Lead
- Total trihalomethanes (TTHM)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Arsenic, nitrate, haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Arizona’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Payson Water - Meads Ranch’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Arizona cover 2020 to 2023.
Testing your own tap
The 3 labs Arizona certifies closest to the area Payson Water - Meads Ranch serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Statewide Laboratory
Mesa, AZ · about 59 miles
Bradshaw Mountain Environmental Inc.
Prescott Valley, AZ · about 61 miles
Legend Technical Services of Arizona, Inc. DBA Legend Analytical
Phoenix, AZ · about 64 miles
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages Arizona supplied to CDC, 2020 to 2023, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or Arizona’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Arizona Department of Health Services, Arizona certified commercial drinking water laboratories, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID AZ0404015. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on ArsenicWhat each one does to health, where it comes from, and the certification claim that addresses it.About Arsenic
- Get the utility’s own reportPayson Water - Meads Ranch must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs