Epcor - Moovalya Keys
What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 1,298 people
- Connections
- 590
- Water source
- Surface water
- Based in
- Parker, AZ
- County
- La Paz
- Owner
- Private
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Lead, above the health goal. 13 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2015 to 2023.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.6 ppm, for the period ending Dec. 31, 2015. None since is on file, so it is not counted as a current finding.
Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Arizona’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.
Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Aug. 20, 2019 to Aug. 20, 2019. Newer results are in the utility’s annual water quality report.
Above the health goal2
Lead
Comes from pipes, often your own
6.2ppb
90th percentile, 2021 to 2023
In the latest period, 9 in 10 homes sampled were at or below 6.2 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic
Comes from the source
2.9ppb
Highest yearly average, 2020
Averaged by year, the highest was 2.9 ppb, in 2020: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.7 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits4
Total trihalomethanes (TTHM)
Forms or is added in treatment
60.5ppb
Highest yearly average, 2020 to 2023
2023 average: 38.3 ppb
Averaged by year, the highest was 60.5 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2023, the latest year on file, it averaged 38.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 83.8 ppb, in 2017, and EPA recorded violations in 2016, 2017 and 2018.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
18.1ppb
Highest yearly average, 2020 to 2023
2023 average: 13 ppb
Averaged by year, the highest was 18.1 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2023, the latest year on file, it averaged 13 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 38.4 ppb, in 2013.
What handles it
No certification claim covers this compound yet.
Fluoride
Forms or is added in treatment
0.3ppm
Highest yearly average, 2019
Averaged by year, the highest was 0.3 ppm, in 2019, below EPA’s legal limit of 4.0 ppm. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.44ppm
Highest yearly average, 2020 to 2023
Averaged by year, the highest was 0.44 ppm, in 2023, below EPA’s legal limit of 10 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.38 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead, Arsenic
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Sept. 1, 2020 to Sept. 30, 2020 | — | Resolved |
| Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | Sept. 1, 2020 to Sept. 30, 2020 | — | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Aug. 1, 2020 to Aug. 31, 2020 | — | Resolved |
| Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | Aug. 1, 2020 to Aug. 31, 2020 | — | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2018 to June 30, 2018 | 0.081 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2018 to March 31, 2018 | 0.089 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2017 to Dec. 31, 2017 | 0.084 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2017 to Sept. 30, 2017 | 0.081 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2017 to June 30, 2017 | 0.082 MG/L | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | Jan. 9, 2017 | — | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2017 to March 31, 2017 | 0.083 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2016 to Dec. 31, 2016 | 0.082 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2016 to Sept. 30, 2016 | 0.089 MG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 23 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Arizona’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Epcor - Moovalya Keys’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Arizona cover 2020 to 2023; EPA’s compliance samples are from Aug. 20, 2019 to Aug. 20, 2019.
Testing your own tap
The lab Arizona certifies closest to the area Epcor - Moovalya Keys serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Mohave Environmental Labs
Bullhead City, AZ · about 74 miles
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages Arizona supplied to CDC, 2020 to 2023, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or Arizona’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Arizona Department of Health Services, Arizona certified commercial drinking water laboratories, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID AZ0415006. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lead
- Get the utility’s own reportEpcor - Moovalya Keys must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs