Skip to content
TapBuff

AK - Chin Village

EPA’s records have results for 38 contaminants in its water; 10 were found.

Serves 11,646 people · Surface water · AK - Chin Village, AZ

Serves
11,646 people
Connections
364
Water source
Surface water
Based in
AK - Chin Village, AZ
Owner
Native American
The 2 ZIP codes it serves

85138, 85139

The short answer

Chromium (total) averaged above its legal limit’s level in 2018, with no violation recorded. Lithium is above EPA’s health benchmark. 3 health-based violations since 2016, 1 with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 3 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from May 17, 2023 to Feb. 22, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2013 to 2025.

Chromium (total), nitrate, total trihalomethanes (TTHM), uranium, haloacetic acids (HAA5), arsenic and fluoride: EPA’s compliance monitoring file, samples taken from Dec. 11, 2012 to Dec. 3, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFHxA at 3.0 ppt: see it below.

Above the limit’s level, no violation recorded, 1 result

Chromium (total)

Comes from the source

Above the limit’s level, no violation

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A filter certified for it, at the tap you drink from, reduces it.

350 ppb

Highest yearly average, 2012 to 2019

2019 average: 18 ppb

Averaged by year, the highest was 350 ppb, in 2018, about 3.5 times EPA’s legal limit of 100 ppb. In 2019, the latest year on file, its five samples averaged below the limit. EPA recorded no violation for chromium (total) at this utility from 2012 to 2019.

How it’s judged

EPA judges this limit on running averages at each sampling point. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap.

What handles it

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

90.8 ppb

Highest sample, Nov. 13, 2023; found in 4 of 4

The highest sample was 90.8 ppb, about 9.1 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 7 results

Uranium, arsenic and lead have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Nitrate, Legal limit 10 ppm; highest 8.3 ppm

Highest sample; found in 17 of 21 · 2019 average: 4.8 ppm · Comes from the source

The highest sample, in 2019, was 8.3 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its six samples averaged below the limit.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 64.5 ppb

Highest yearly average, 2012 to 2019 · 2019 average: 49.7 ppb · Forms or is added in treatment

Averaged by year, the highest was 64.5 ppb, in 2014, below EPA’s legal limit of 80 ppb. Its highest single sample was 86 ppb. In 2019, the latest year on file, its eight samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility from 2012 to 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 10.8 ppb

Highest yearly average, 2012 to 2019 · Comes from the source

Averaged by year, the highest was 10.8 ppb, in 2019, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 19.6 ppb. That was also the latest year on file.

What handles it

About uranium
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 20.3 ppb

Highest yearly average, 2012 to 2019 · 2019 average: 9.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 20.3 ppb, in 2013, below EPA’s legal limit of 60 ppb. Its highest single sample was 42 ppb. In 2019, the latest year on file, its eight samples averaged below the limit.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 2.8 ppb

Highest yearly average, 2014 to 2019 · 2019: not found · Comes from the source

Averaged by year, the highest was 2.8 ppb, in 2014, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2019, the latest year on file, it wasn’t found in any of its two samples.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.9 ppm

Highest yearly average, 2012 to 2019 · 2019 average: 0.55 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.9 ppm, in 2014, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 1.1 ppm. In 2019, the latest year on file, its two samples averaged below the limit.

What handles it

About fluoride
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.0 ppb

90th percentile, 2023 to 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Arizona utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFHxA3.0 ppt1 of 4None covers it
28 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

3 health-based violations since 2016, 2 for the Interim Enhanced Surface Water Treatment Rule and 1 for the Stage 1 Disinfectants and Disinfection Byproducts Rule. The latest began April 1, 2026, and 1 has no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Stage 1 Disinfectants and Disinfection Byproducts RuleTreatment was not run by a certified operator as required.EPA: Treatment Technique No Certif. OperatorApril 1, 2026No fix on recordEPA: unaddressed
Interim Enhanced Surface Water Treatment RuleToo many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR)Nov. 1, 2025 to Nov. 30, 2025Resolved
Interim Enhanced Surface Water Treatment RuleOne cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR)July 1, 2017 to July 31, 2017Resolved

Health-based violations only. 6 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies: “Chromium Reduction” on one listing can read “Chromium (Trivalent) Reduction” on another.

  • NSF/ANSI 53

    Claims: Chromium Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Chromium (total), Arsenic, Lead

    Other certifiers’ wording: Chromium (Trivalent) Reduction

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Chromium (Hexavalent) Reduction, Uranium, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Chromium (total), Uranium, Arsenic, Lead

    Other certifiers’ wording: Chromium (Trivalent) Reduction

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for chromium-6, ranked⁠

The best reverse osmosis systems, ranked⁠

The best water filters for lead, ranked⁠

Disinfectant

AK - Chin Village reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 to 2024 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Newer results, and everything else. Nitrate, arsenic, fluoride, chromium, uranium and disinfection byproduct results here come from EPA’s national compliance file, which ends in 2019. AK - Chin Village’s own annual report, which it must send you every year, has newer results and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from May 17, 2023 to Feb. 22, 2024; EPA’s compliance samples are from Dec. 11, 2012 to Dec. 3, 2019.

Testing your own tap

AK - Chin Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Arizona certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. AK - Chin Village’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 1.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What AK - Chin Village’s results flag: chromium (total) and lithium. These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs Arizona certifies closest to the area AK - Chin Village serves, or a kit by mail

The 3 labs Arizona certifies closest to the area AK - Chin Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

All 49 certified labs for Arizona⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Arizona certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Arizona’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID 090400090. Rebuilt from EPA data on Oct. 25, 2026.