Kathy O Estates
EPA’s and Alaska’s records have results for 7 contaminants in its water; 4 were found.
Serves 242 people · Groundwater · Anchorage, AK
- Serves
- 242 people
- Connections
- 78
- Water source
- Groundwater
- Based in
- Anchorage, AK
- County
- Anchorage Municipality
- Owner
- Private
The ZIP code it serves
The short answer
Arsenic averaged above its legal limit’s level in 2023, with no violation recorded. 5 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What handles itThe 5 violationsGot a notice? What it means
What was found
Where these results come from, and when
Lead and copper: EPA SDWIS monitoring periods ending 2000 to 2025.
Arsenic, total trihalomethanes (TTHM), nitrate and haloacetic acids (HAA5): Alaska’s own results, samples taken from Jan. 21, 2020 to Jan. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.
Chromium (total) and fluoride: EPA’s compliance monitoring file, samples taken from April 4, 2019 to April 4, 2019. Newer results are in the utility’s annual water quality report.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
Above the limit’s level, no violation recorded, 1 result
Arsenic
Comes from the source
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A filter certified for it, at the tap you drink from, reduces it.
13.9 ppb
Highest yearly average, 2023 to 2025
2025, one sample: 1.6 ppb
Averaged by year, the highest was 13.9 ppb, in 2023, above EPA’s legal limit of 10 ppb. Its highest single sample was 38 ppb. In 2025, the latest year on file, its one sample was below the limit. EPA recorded no violation for arsenic at this utility since 2020.
How it’s judged
EPA judges this limit on running averages at each sampling point. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.7 ppb, in 2014.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits, 3 results
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 3.0 ppb
90th percentile, 2023 to 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 1.1 ppb
Highest yearly average, 2020 to 2023 · Forms or is added in treatment
Averaged by year, the highest was 1.1 ppb, in 2023, below EPA’s legal limit of 80 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate, Legal limit 10 ppm; highest 0.073 ppm
Highest sample; found in 1 of 7 · 2026, one sample: 0.073 ppm · Comes from the source
The highest sample, in 2026, was 0.073 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Fluoride
- Haloacetic acids (HAA5)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Arsenic; also lead, found below its limits
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Arsenic; also lead, found below its limits
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Arsenic; also lead, found below its limits
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Arsenic; also lead, found below its limits
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for lead only, found below its limits
Every filter certified for it
Violations since 2016
5 health-based violations since 2016, all for the Groundwater Rule. The latest began Dec. 1, 2024.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | Dec. 1, 2024 | Resolved |
| July 29, 2019 | Resolved | ||
| July 29, 2019 | Resolved | ||
| July 29, 2019 | Resolved | ||
| July 29, 2019 | Resolved |
Health-based violations only. 12 monitoring or reporting violations not shown.
What this report can’t tell you
Everything else. Arsenic, total trihalomethanes (TTHM), nitrate and haloacetic acids (HAA5) results here are Alaska’s own from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total) and fluoride come from EPA’s file alone, which ends in 2019. Kathy O Estates’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Alaska’s results run from Jan. 21, 2020 to Jan. 6, 2026; EPA’s compliance samples are from April 4 to 4, 2019.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Kathy O Estates’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 3.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Kathy O Estates’s results flag: arsenic. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
Labs Alaska certifies, or a kit by mail
No lab Alaska certifies is within 75 miles of the area Kathy O Estates serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 37 certified labs for AlaskaOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Alaska certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Alaska’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on arsenicWhat it does to health, where it comes from, and the certification claim that addresses it.About arsenic
- Get the utility’s own reportKathy O Estates must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Alaska Department of Environmental Conservation, Drinking Water Viewer, results from Jan. 4, 2020 to Oct. 14, 2026, read Oct. 24, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID AK2211897. Rebuilt from EPA data on Oct. 25, 2026.